15
2.5.6 Connecting to an auxiliary device = AUX 1 - Dry contact provided for disconnection from the 230V
power supply
The chlorinator manages a dry contact calibrated for disconnection from the 230V power supply. The power
supply is separated with its own protection (circuit breaker calibrated to suit the equipment controlled or its
transformer – max. 8 A).
Preferred connection for NL LED spotlights.
Possible controls:
ON/OFF with timer for all monochromatic spotlights, ON/OFF/Colour with NL RGBW LED
spotlights
230 V contact
All types of auxiliary
device
230 V
Transformer for lighting,
booster pump, etc.
maximum 8 A
Preferred connection for Zodiac® NL LED spotlights (see
installation manual)
: 230 VAC / 12 VAC
(50/60 Hz) transformer
: Electrical protection
: Auxiliary relay for
external controller or
switch
With 2 spotlights
With 1 spotlight