background image

Français

English

Deutsch

Nederlands

Español

Português

Italiano

SENSOR 

#1

Sonde de 

température 

ambiante et 

hygrométrie

Ambient 

temperature and 

humidity sensor

Raumtemperatur- und 

Luftfeuchtigkeitsfühler

Omgevingstemperatuur- 

en vochtigheidssensor

Sonda de 

temperatura 

ambiente y de 

higrometría

Sonda de 

temperatura 

ambiente e 

higrometria

Sonda di 

temperatura e di 

igrometria

SENSOR 

#2

Sonde de 

dégivrage 

Defrost sensor 

Abtaufühler

Ontdooiingssensor

Sonda de 

deshielo 

Sonda de degelo 

Sonda 
sbrinamento 

TC 

SENSOR

Sonde de 

température du 

compresseur 

(prévention de la 

surchauffe)

Compressor 

temperature 

sensor 

(overheating 

protection)

Kompressor-

temperaturfühler 

(Überhitzungsschutz)

Temperatuursensor 

van de compressor 

(voorkoming van 

oververhitting)

Sonda de 

temperatura 

del compresor 

(prevención 

de sobre-

calentamiento)

Sonda de 

temperatura 

do compressor 

(prevenção 

do sobre-

aquecimento)

Sonda di 

temperatura del 

compressore 

(prevenzione del 

surriscaldamento)

YELLOW

Jaune

Yellow

Gelb

Geel

Amarillo

Amarelo

Giallo

WHITE

Blanc

White 

Weiß

Wit

Blanco

Branco

Bianco

BLACK

Noir

Black

Schwarz

Zwart

Negro

Preto

Nero

BROWN

Marron

Brown

Braun

Bruin

Marrón

Castanho

Marrone

RED

Rouge

Red

Rot

Ross

Rojo

Vermelho

Rosso

FAN 

MOTOR

Moteur 

ventilateur 

Fan motor

Lüftermotor

Motor ventilator

Motor 

ventilador

Motor ventilador

Motore 

ventilatore

C1

Condensateur 

ventilateur

Fan capacitor

Lüfterkondensator

Condensator ventilator

Condensador 

ventilador

Condensador 

ventilador

Condensatore 

ventilatore

C2

Condensateur 

compresseur 

Compressor 

capacitor

Betriebskondensator
für Kompressor

Compressorcondensator

Condensador 

compresor

Condensador 

compressor

Condensatore 

compressore

SOURCE

Prise électrique

Electric plug

Stromsteckdose

Stopcontact

Toma eléctrica

Tomada elétrica

Presa elettrica

COMP

Moteur 

compresseur 

Compressor 
motor

Kompressormotor

Compressormotor

Motor 

compresor

Motor 

compressor

Motore 

compressore

OVERLOAD 

PROTECTOR

Protection anti-

surcharge

Overload 

protector

Überlastschutz

Overbelastingsbeveiliging Protección de 

sobrecarga

Proteção anti-

sobrecarga

Protezione anti-

sovraccarico

ACL-ACN

Alimentation 

monophasée 

230Vac-1N-50Hz

Single-phase 

power supply 

230Vac-1N-50Hz

Einphasige 

Stromversorgung 230 

V AC -1N-50Hz

Eenfasevoeding 230 VAC 

- 1 N - 50 Hz

Alimentación 

monofásica 230 

Vac-1 N-50 Hz

Alimentação 

monofásica 

230Vac-1N-50Hz

Alimentazione 

monofase 230Vac-

1N-50Hz

Terre

Earth

Erde

Aarde

Tierra

Terra

Terra

MICRO

SWITCH

Microrupteur 

Microswitch

Mikroschalter

Microschakelaar

Micro 

interruptor

Micro-interruptor Microinterruttore

CONTROL

PANEL

Interface 

Utilisateur

User interface

Bedieneinheit

Gebruiksinterface

Interfaz de 

usuario

Interface 

Utilizador

Interfaccia utente

Summary of Contents for DT850E

Page 1: ...H0369900_REVC 2021 01 More documents on www zodiac com DT 850 E EN Instructions for installation and use English Dehumidifier Translation of the original instructions in French...

Page 2: ...ledge and experience unless they receive supervision or prior instructions on using the appliance from a person responsible for their safety Children must be supervised to ensure that they do not play...

Page 3: ...ny extension lead when connecting the appliance connect the appliance directly to a suitable power supply Before carrying out any operations check that The required input voltage indicated on the appl...

Page 4: ...thermo dynamic and acoustic performance LABELLING The equipment must be labelled so as to specify that it is out of order and that the refrigerant has been drained The label must be dated and signed F...

Page 5: ...st be carried out before returning the compressor to the supplier Only the electric heater of the compressor body can be used to accelerate this process This operation can be carried out safely once a...

Page 6: ...nciple 10 3 2 I User interface presentation 10 3 3 I Starting the appliance 11 Maintenance 12 4 1 I Maintenance 12 Troubleshooting 15 5 1 I Appliance behaviour 15 5 2 I Electrical diagram 15 Tip to ma...

Page 7: ...1 1 I Description DT 850 E Anti vibration studs round Anti vibration studs rectangular Screw Plugs Mounting bracket Included 1 2 I Dimensions and marking 750 mm 345 mm 660 mm Suction grid Blower grid...

Page 8: ...ound pressure at 1 m db A 20 Approximate weight kg 37 Cooling fluid R290 Cooling fluid load kg 0 3 Service pressure min max bar 8 5 22 MPa 0 85 2 2 Operating range of pool room C 7 35 Protection ratin...

Page 9: ...s pool room high relative humidity During building make sure that the materials used are compatible with a swimming pool environment the walls are sufficiently waterproofed and insulated to prevent co...

Page 10: ...acket and the appliance to avoid vibrations spreading through the wall Fix the 2 supplied round anti vibration studs in the intended locations at the bottom corners of the appliance s rear panel Faste...

Page 11: ...work with impedance under 0 095 ohm The power supply must correspond to the voltage indicated on the appliance s information plate The power cord must be insulated against any cutting or hot elements...

Page 12: ...ation see 2 1 3 Connecting the condensate drainage line After a 5 minute delay if the level of ambient humidity is higher than the desired humidity level the compressor starts up and the COMP indicato...

Page 13: ...create a fire or explosion risk All possible ignition sources in particular cigarettes must not enter within a sufficient perimeter of the installation repair removal or disposal site in the event tha...

Page 14: ...ed The leak detection equipment must be adjusted to a percentage of the refrigerant s LFL and must be calibrated according to the refrigerant used The appropriate gas percentage 25 at most must be con...

Page 15: ...fill the cylinders no more than 80 of the volume must be filled with liquid 9 Do not exceed the maximum working pressure of the cylinder even temporarily 10 When the cylinders have been filled correct...

Page 16: ...dynamic principle which transforms part of the absorbed energy into heat which is then transferred to the ventilated air flow The appliance begins defrost ing The dehumidifier s cooling circuit is aff...

Page 17: ...5 2I Sch ma lectrique Electricaldiagram Schaltplan Bedradingschema Esquemael ctrico Esquema el ctrico Schema elettrico...

Page 18: ...or L ftermotor Motor ventilator Motor ventilador Motor ventilador Motore ventilatore C1 Condensateur ventilateur Fan capacitor L fterkondensator Condensator ventilator Condensador ventilador Condensad...

Page 19: ...rty of their respective owners Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d informations enregistrement produit et support client For more in...

Reviews: