5.1 I Appliance behaviour

The appliance is discharging 

water

The  appliance  is  discharging  water,  known  as  condensates.  This  water  is  the

humidity your dehumidifier condenses to dry the air.

The appliance is working but 

the windows are covered in 

water

• This is the dew point, which is the point at which the water vapour contained in

the air changes states when in contact with a cold surface. This is known as the

phenomenon of condensation. This does not mean your appliance is not working.

This phenomenon is normal, because of the presence of humidity in the air (65%

humidity in comfortable conditions), and a cold outside temperature.

The dehumidifier blows hot 

air even though the heating 

is absent or deactivated

The  dehumidification  function  is  based  on  the  thermodynamic  principle  which

transforms part of the absorbed energy into heat, which is then transferred to the

ventilated air flow.

The appliance begins defrost-

ing

The  dehumidifier's  cooling  circuit  is  affected  by  the  local  operating  conditions.

Lower temperatures and the moisture content of the ambient air are more likely

to create frost.

To  ensure  its  correct  operation,  the  appliance  eliminates  all  traces  of  frost  by

initiating a short defrosting cycle lasting a few minutes.

The ventilation stays on even 

when the setpoint tempera

-

ture(s) have been reached

Ventilation  continues  for  a  few  minutes  after  the  temperature  and  humidity

setpoints have been reached. This optimises the appliance's efficiency by evacuating

the residual calories in the batteries that are still hot.

The  dehumidifier  is  not 

working

Check it is correctly connected.

• Make sure the hygrostat is on.

The appliance is noisy

Make sure the appliance is solidly installed and is level.

If the problem is not resolved, contact your retailer.

5.2 I 

Electrical diagram

Wiring diagram is available at the end of the document, see § 5.2 Schéma électrique / Wiring diagram /

Schaltplan / Elektrischschema / Esquema eléctrico / Esquema eléctrico / Schema elettrico.

Summary of Contents for DT850E

Page 1: ...H0369900_REVC 2021 01 More documents on www zodiac com DT 850 E EN Instructions for installation and use English Dehumidifier Translation of the original instructions in French...

Page 2: ...ledge and experience unless they receive supervision or prior instructions on using the appliance from a person responsible for their safety Children must be supervised to ensure that they do not play...

Page 3: ...ny extension lead when connecting the appliance connect the appliance directly to a suitable power supply Before carrying out any operations check that The required input voltage indicated on the appl...

Page 4: ...thermo dynamic and acoustic performance LABELLING The equipment must be labelled so as to specify that it is out of order and that the refrigerant has been drained The label must be dated and signed F...

Page 5: ...st be carried out before returning the compressor to the supplier Only the electric heater of the compressor body can be used to accelerate this process This operation can be carried out safely once a...

Page 6: ...nciple 10 3 2 I User interface presentation 10 3 3 I Starting the appliance 11 Maintenance 12 4 1 I Maintenance 12 Troubleshooting 15 5 1 I Appliance behaviour 15 5 2 I Electrical diagram 15 Tip to ma...

Page 7: ...1 1 I Description DT 850 E Anti vibration studs round Anti vibration studs rectangular Screw Plugs Mounting bracket Included 1 2 I Dimensions and marking 750 mm 345 mm 660 mm Suction grid Blower grid...

Page 8: ...ound pressure at 1 m db A 20 Approximate weight kg 37 Cooling fluid R290 Cooling fluid load kg 0 3 Service pressure min max bar 8 5 22 MPa 0 85 2 2 Operating range of pool room C 7 35 Protection ratin...

Page 9: ...s pool room high relative humidity During building make sure that the materials used are compatible with a swimming pool environment the walls are sufficiently waterproofed and insulated to prevent co...

Page 10: ...acket and the appliance to avoid vibrations spreading through the wall Fix the 2 supplied round anti vibration studs in the intended locations at the bottom corners of the appliance s rear panel Faste...

Page 11: ...work with impedance under 0 095 ohm The power supply must correspond to the voltage indicated on the appliance s information plate The power cord must be insulated against any cutting or hot elements...

Page 12: ...ation see 2 1 3 Connecting the condensate drainage line After a 5 minute delay if the level of ambient humidity is higher than the desired humidity level the compressor starts up and the COMP indicato...

Page 13: ...create a fire or explosion risk All possible ignition sources in particular cigarettes must not enter within a sufficient perimeter of the installation repair removal or disposal site in the event tha...

Page 14: ...ed The leak detection equipment must be adjusted to a percentage of the refrigerant s LFL and must be calibrated according to the refrigerant used The appropriate gas percentage 25 at most must be con...

Page 15: ...fill the cylinders no more than 80 of the volume must be filled with liquid 9 Do not exceed the maximum working pressure of the cylinder even temporarily 10 When the cylinders have been filled correct...

Page 16: ...dynamic principle which transforms part of the absorbed energy into heat which is then transferred to the ventilated air flow The appliance begins defrost ing The dehumidifier s cooling circuit is aff...

Page 17: ...5 2I Sch ma lectrique Electricaldiagram Schaltplan Bedradingschema Esquemael ctrico Esquema el ctrico Schema elettrico...

Page 18: ...or L ftermotor Motor ventilator Motor ventilador Motor ventilador Motore ventilatore C1 Condensateur ventilateur Fan capacitor L fterkondensator Condensator ventilator Condensador ventilador Condensad...

Page 19: ...rty of their respective owners Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d informations enregistrement produit et support client For more in...

Reviews: