![Zmotion ZMC306N Manual Download Page 29](http://html1.mh-extra.com/html/zmotion/zmc306n/zmc306n_manual_3939669029.webp)
ZMC306N Motion Controller User Manual V1.5
Note:
The times in the form are typical based on the resistive load, and may change
when the load circuit changes.
Due to the leak-type output, the shutdown of the output will be obviously
affected by the external load circuit, and the output frequency should not be set
too high in the application.
→
Wiring Reference
→
Wiring Note:
⚫
The wiring principle of high-speed digital output OUT (0-3) and low-speed digital
output OUT4-11 is shown in the figure above. The external signal receiving end can
be an optocoupler or a relay or solenoid valve, all can be connected as long as the
input current does not exceed 300mA.
⚫
For the connection of the common terminal, please select the "EGND" port on the IO
power terminal to connect to the negative pole of the DC power supply of the external
input device. If the DC power supply of the external device and the controller power
supply are in the same power supply system, this connection can also be omitted.
⚫
The E5V port is a 5V power output port, which can be used when some loads need to
provide an external 5V power input, the maximum current is 300mA.