XPCIE1028 Motion Control Card User Manual V1.0
input OUT (16-31) is shown in the figure above. The external signal source can be an
optocoupler, a relay or a solenoid valve etc., all can be connected as long as the input
current is not more than 300mA.
⚫
For the public end, please connect the "EGND" port on the power supply to the
negative pole of DC power supply of external input device. If the signal area power
supply of the external device and the power supply of the controller are in the same
power supply system, this connection also can be omitted.
⚫
The E24V port is the freewheeling clamp port of this part of the digital output port.
When this port is suspended, each output port will not have the freewheeling function.
It needs to be connected to the positive pole of the load power supply to enable this
function.
⚫
The E5V port is a 5V power output port, which can be used when some loads that
need to provide an external 5V power input, and the maximum current is 300mA.
3.6.2.
Basic Usage Method
1.
Please follow the above wiring instructions to wiring correctly.
2.
After powered on, please connect to ZDevelop.
3.
Open or close output port directly through “OP” command, also, it can be opened or
closed thr
ough “ZDevelop/View/Op”. Please refer to “ZBasic” for details.