INSTALLATION OF THE SYSTEM.
5.1.
REQUIREMENTS FOR INSTALLATION OF PELLET BURNER WITH SELF-
CLEANNING “GP XX SC” TO A HOT WATER BOILER “PELLETHERM V.4 LT”.
The automated pellet burner from series “GP xx sc” is usually mounted on the heat
exchanger unit of a hot water boiler from series “Pelletherm V.4 LT”. The construction of the
boiler provides opportunity only for “left” or “right” mounting of the burner. Therefore the right
combination choice should be made at the stage when the project is being prepared. During
installation it is important to ensure perfect sealing between the described
components/modules, in order to prevent intake of air from the environment or exhaust of
flue gasses.
During the burner installation the following requirements must be observed:
Access to the burner’s fire-grate for easy cleaning;
Provide safe operation conditions and maintain reliability of the system;
Availability for adjustment and maintenance of the system: heat exchanging unit of
hot water boiler from series “Pelletherm V.4 LT” (example: when need to clean);
burner from series “GP xx sc” – during adjustment and maintenance; fuel transport
auger – during servicing and maintenance; fuel hopper – during refueling or when
needed to clean it.
5.2.
GENERAL INFORMATION FOR CO-OPERATION OF THE SYSTEM: A HOT
WATER PELLET BOILER “PELLETHERM V.4 LT” AND PELLET BURNER FROM
SERIES “GP XX SC”.
The realized heating output of the system – a hot water pellet boiler from series “Pelletherm
V.4 LT” and an automated pellet burner from series “GP xx sc”, depends on:
The adjusted operational heating output of the burner;
The contamination level on the boiler’s heat-exchanging surfaces;
The sealing level of the boiler combustion chamber’s door and cover panels
(condition of sealing ropes);
The chimney draught.
The efficiency coefficient of the system, a hot water pellet boiler from series “Pelletherm V.4
LT” and an automated pellet burner from series “GP xx sc”, in nominal operation mode
reaches 89% (depending on the system specifics) – can be reached by adjustment of the
burner’s operational parameters through gas analyzer (performed by an authorized
specialist).
5.3.
INSTALLATION AND CONNECTION OF A HOT WATER PELLET BOILER
“PELLETHERM V.4 LT” AND PELLET BURNER “GP XX SC”.
5.3.1.
MAIN REQUIREMENTS FOR INSTALLATION OF A HOT WATER PELLET
“PELLETHERM V.4 LT”.
The following main requirements must be observed during installation of a hot water pellet
boiler from series “Pelletherm V.4 LT”:
The room, designated for installation of the system, must provide constant intake of
fresh air, needed for the burning process and for ventilation;
It is not allowed to install the system in living premises, including corridors;
The hot water boiler from series “Pelletherm V.4 LT” connection to the heating system
must be performed only by a qualified technician;
The solid fuel appliances installation and maintenance must be performed only by
specialized companies, legally authorized for such activities;
The hot water boiler from series “Pelletherm V.4 LT” should be connected to the
heating installation either with CLOSED expansion tank. In case the system is with
closed expansion tank, then additional pressure safety valve must be installed, which