Pelletherm V.4 LT
10
The dimensions and additional technical parameters of the system – hot water pellet boiler
from series “Pelletherm V.4 LT” and automated pellet burner from series “GP xx sc”, are
presented on Figure 4.1 and in Table 4.2.
Figure 4.1. Dimensions of the system hot water pellet boiler and automated pellet burner.
Table 4.2. Dimensions and additional technical parameters of the system hot water pellet
boiler and automated pellet burner.
PARAMETER
DIMENSION
VALUE
Hot water pellet boiler model
-
Pelletherm
18 V.4 LT
Pelletherm
25 V.4 LT
Pelletherm
30 V.4 LT
Automated pellet burner model
-
GP 20_18 sc
GP 25 sc
GP 32 sc
Boiler weight
kg
342
342
362
Boiler water volume
l
50
50
60
System overall dimensions: B
546
1080
780
1250
546
546
546
W
1080
1080
1080
D
780
780
780
H
1250
1330
1330
Boiler’s operational water
overpressure
MPa
0.25
Boiler’s tested overpressure
MPa
0.40
Recommended operational water
temperature in the boiler
ºC
80
Minimum boiler inlet water
temperature
ºC
60
Chimney draught
Pa
17
Connection
lines
Inlet/Outlet water
G
1½”
Flue outlet
diameter
mm
149
System power supply
-
L1, N, PE, 50Hz; 230VAC;
System electrical output
W
<100
+1100
(+ at ignition)
System electrical protection
-
IP20
If the chimney draught operation value is below the recommended values,
presented in the above table, it is necessary to install additional extraction fan
module.