CP-S: E512 – INTERCEPTOR NOT CONNECTED 

POSSIBLE CAUSES AND CORRECTIVE ACTIONS

 

1RLQWHUFHSWRULVFRQQHFWHGWRWKH'86

  1. 

Connect at least one interceptor to complete the system installation.

 

$QLQVWDOODWLRQZLWKRGGQXPEHURILQWHUFHSWRUVDUHQRWFRUUHFWO\FRQQHFWHGWRWKH'86

  1. 

Connect the interceptor pairs to the DU-S starting at PORT/STBD 1. 

  2. 

Connect the single (centerline mounted) interceptor to the PORT3 connector at the DU-S

 

   

(see illustration below).

 

$FRQQHFWHGVHUYRXQLWLVQRWLGHQWL²HGE\WKHV\VWHP

  1. 

Check that the system units listed in the CP-S under ’System Information’ agrees with the

 

   

actually connected units.

  2. 

Check cable and connectors for dirt or damage. Try connecting SU-S to a different connector of 

 

   

the DU-S. Replace any damaged cables/units. 

  3. 

Verify function of the servo units individually by disconnect all and reconnecting them one-by-one 

 

   

to DU-S at the PORT3 connector.

  4. 

Replace any failing servo unit that does not get recognized by the system or otherwise does not    

    operate 

properly.

  The system cannot identify interceptor or interceptor pairs.

ERROR CODE TRIGGER

9

Installations with a centerline interceptor connected to DU-S PORT 3.

Port interceptor 1 not identified by the system.

Summary of Contents for S Series

Page 1: ...TROUBLE SHOOTING GUIDE...

Page 2: ...TROUBEL SHOOTING GUIDE DYNAMIC TRIM CONTROL SYSTEM SERIES S Release R1A April 2019 Language English Copyright 2019 Zipwake AB Sweden All rights reserved www zipwake com...

Page 3: ...r individual sets of error codes bit encoded The Distribution Unit DU S do not generate any error codes Presence of system error is indicated in the CP S display by a flashing red info symbol in combi...

Page 4: ...er cooler location 64 GPS error No GPS signal Check GPS source and GPS status on the Select GPS source menu page norm set to Auto GPS signal is acquired received If an external GPS or NMEA 2000 GPS is...

Page 5: ...d check that the blades are moving correctly run Interceptor Check 64 Electronics failure Electronics failure Restart the system power turned on main switch toggle Visit www zipwake com for upgrades r...

Page 6: ...supply issue see previous check list 2 Check if the SU S that reports error operates makes any movement at system turn on 3 Replace SU S if confirmed it is not operating 6HUYR XQLW V VFUHZ VKDIW KDV E...

Page 7: ...ase of any indication the blades are obstructed Interceptor Check readout not in the green range check for excessive marine growth dirt paint or sealant on interceptor s moving parts 2 Remove the Inte...

Page 8: ...DFKHG GXULQJ 68 6 VWDUWXS VHTXHQFH 1 Remove any obstacles growth dirt mud paint etc that prevents the interceptor blade to fully retract 2 Check and verify the SU S is mounted with the screw shaft nut...

Page 9: ...1 Check that the system units listed in the CP S under System Information agrees with the actually connected units 2 Check cable and connectors for dirt or damage Try connecting SU S to a different c...

Page 10: ...onnect all units in the system except one CP S connected to the DU S on the I BUS OUT connection 2 Connect the SU S units one by one to the DU S at PORT3 connection and identify which SU S that trigge...

Page 11: ...h designated torque 5 Nm Run the Interceptor Check and verify that the blades are moving freely within tolerance range all the readings of Interceptor Check are in green range Document and archive the...

Page 12: ......

Reviews: