CP-S ERROR CODES
4
Series S Control Panel (CP-S)
Blt
Description
Error message displayed
Corrective actions
Error code is cleared when...
code
on control panel
1
Low voltage detect
Supply voltage too low
• Check battery supply voltage (>12V).
...supply voltage goes above 9V.
• Check the power cable connection to the battery.
2
High voltage detect
Supply voltage too high
• Check the distribution unit power cable.
...supply voltage goes below 32V.
• Check battery supply voltage (12-32V).
4
Rotary encoder failure
Button/wheel failure
• Check if any buttons or wheels are stuck.
...power turned on (main switch toggle).
• Use fresh water to spray and remove any dirt on the control panel front.
8
Accelerometer failure
Acc/gyro error
• Turn off the sustem for 10 minutes, then restart.
...power turned on (main switch toggle).
16
Gyro failure
Acc/gyro error
• Turn off the sustem for 10 minutes, then restart.
...power turned on (main switch toggle).
32
High circuitboard temp
Panel temp. too high
• Check if the panel is mounted close to any heat source.
...circuitboard temperature goes below 75°C.
• Try mounting the panel in another (cooler) location.
64
GPS error
No GPS signal
• Check GPS source and GPS status on the Select GPS source menu page (norm. set to Auto).
...GPS signal is acquired (received).
• If an external GPS or NMEA 2000 GPS is installed, check the cables for damage.
• Check the NMEA 2000 GPS source is turned on.
• Clean and reattach the control panel connectors.
128
Software exception error
Program error
• Restart the system.
...power turned on (main switch toggle).
• Visit www.zipwake.com for upgrades resolving the issue.
256
<not
used>
512
Too few interceptors
Interceptor not connected
• Check the servo cables for damage.
...more than one servo unit detected (connected).
• Clean and reattach the connectors on the distribution unit.
...a single interceptor is detected (connected) at PORT 3.
• Ensure a single interceptor installation is connected to distribution unit PORT 3.
1024
CAN-bus error
Communication error
• Check the system cables for damage.
...I-BUS communication is restored.
- Clean and reattach the connectors on the distribution unit and control panels.
• Identify failing component.
- Disconnect all interceptors and flybridge control panels.
- Reconnect units one-by-one to identify which unit triggers error.
Note: connect the interceptor one-by-one to DU at PORT 3 to avoid triggering error code E512
- Replace failing unit.
Summary of Contents for S Series
Page 1: ...TROUBLE SHOOTING GUIDE...