24
1.6
Maintenance
A C H T U N G
No cleaning, upkeep or maintenance activities allowed when machine is running!
Therefore: Prior to any maintenance, switch the power generator off!
The ZI-STE900IV is a low-maintenance machine. Follow the general rules of operation and up-
keep of combustion engines. Disturbances in operation and defects have to be corrected immedi-
ately. Servicing and Repair only by trained persons!
1.6.1
Upkeep and Maintenance plan
Control for defect or loose parts
Prior to every operation
Clean the machine
After every operation
Check (and clean if necessary) spark plug
every 25 operating hours
Clean air filter
every 20-30 operating hour
Clean exhaust
every 50 operating hour
1.6.2
Cleaning
.
H I N W E I S
Do not use thinners, aggressive solvents or detergents for cleaning. This
damages the machine.
Clean only with a damp cloth
1.6.3
Clean spark plug
Take of the spark plug cover. Carefully loosen the spark plug (K) and remove it. Clean it with a
small brush, remove soot debris etc.
Check the spark contacts distance. It should have ~ 0.6mm (or approx. credit card thickness)
Summary of Contents for ZI-STE900IV
Page 4: ...4 ...
Page 5: ...5 ...
Page 16: ...16 1 8 Fehlerbehebung ...
Page 26: ...26 1 8 Trouble Shooting ...
Page 35: ...35 1 16 Odstranění závad 1 16 1 Diagram odstranění závad na motoru ...
Page 36: ...36 1 16 2 Diagram odstranění závad na generátoru ...
Page 38: ...38 ...