17
806393 v1.08 09.19 Micro Install Instructions
Operation
Energy mode
To enable/disable energy mode, press the button on
the front of the command centre. The green light
will illuminate when energy mode is enabled.
When energy mode is enabled, after 2 hours of
inactivity, the boiling tank set point temperature is
reduced to 68°C, to conserve energy.
If the tap is operated to dispense boiling water, the
boiling set point temperature is restored to 98°C.
Allow time for the water to return to the set point
temperature.
POWER
ENERGY MODE