15
806393 v1.08 09.19 Micro Install Instructions
8
FIL
TE
RE
D
FILT
ER
FL
US
H
Commissioning
7
While the LCD flashes “F”, press and hold the
button. Water will flow through the filter and out
the hose. The “F” displayed will stay on.
Continue holding the button. The button may be
released to temporarily stop water flow.
After 2 minutes (10 litres), water flow will
stop. The LCD shows “P” and filter life will be
reset to zero. Release the button.
9
Turn filter valve key
to FILTERED
Return filter valve
key to holder.
Refit front
cover
10
10L bucket
Before first use:
Check for leaks. Allow 5 minutes
for tanks to fill. Flush with fresh water
to remove any residue from factory
sanitisation.
• (All models) Dispense 1.8 litres
of boiling water from the tap,
equivalent to a complete tankful of
water. Repeat 3 times.
• (BC model) Dispense 1.8 litres
of chilled water from the tap,
equivalent to a complete tankful of
water. Repeat 3 times.
11
Remove the filter flush hose, dry
it and return to storage.
WARNING: Ensure flush valve
is rotated to “FILTERED” before
normal operation, to prevent
unwanted water flow.
Turn power off to the command
centre, wait 10 seconds, then power on
again. Wait a further 30 seconds for the
blue “POWER” light to illuminate.
Power cycle
!