806393 v1.08 09.19 Micro Install Instructions
Installation instructions
The HydroTap Micro must be installed with an isolation valve (not
supplied) to the mains water supply, for servicing.
Use the new hose sets supplied. Do not re-use old hose sets.
Flush all water supply lines before connecting, to prevent sediment
from affecting operation.
1
2
Connect electrical
power cable to
a 220-240V AC, 10A
power outlet.
3
Connect the USB cable from the
tap to the command centre.
Connect the 350 kPa
PLV to the mains water
supply, applying sealant
tape to the thread.
Mains water isolation
valve remains OFF.
Connect the braided hose to the PLV.
At the top of the command centre,
remove plug from MAINS IN. Connect
the other end of the braided hose.
MAINS IN
CHILLED OUT
BOILING OUT
VENT
MAINS IN
OFF
OFF
Quick-connect
fitting:
push
the hose in as
far as it will go