Zip Hydro Tap Installation and Operating Instructions - 81759 - February 2013 v2.01
Page 7 of 16
Installation procedure
continued
Step D - Connecting the water supply
To prevent sediment from entering the Zip HydroTap at connection, flush water
through the supply line thoroughly before connection to the Zip HydroTap.
Open the access door and check that the filter is in place and secure. Connect
the water supply to the undersink unit using the supplied flexible hose .Turn
on water and check for leaks. If no leaks are evident turn the power on. The
Blue L.E.D. flashes slowly on the Tap head assembly.
Step E - Testing and commissioning
Filter Flush Mode :
The display screen will show which model you have.
Have a bucket or similar container (not supplied) at the ready to hold a quantity
of water that is ejected while the Filter Flush Mode is in operation. Open the
filter access door on the front of the HydroTap and the filter cartridge will be
exposed. Located to the rear RHS of the cartridge is a fixed flush line, approx
600mm long and the flush line stop cock. Place the free end of the flush line
into the bucket or container (not supplied).
The display will show Filter Flush Mode. Open the flush line stop cock. To
activate press adjust
>
. Run at least 7.5 Ltrs of water through to activate
the filter membrane. Press the adjust
>
button again to stop the Filter Flush
Mode. Turn OFF the Filter Flush stop cock and re-locate the tube and stop
cock in the filter compartment. Turning OFF the Filter Flush Mode puts the
HydroTap into normal operation. Press adjust
>
to start normal operation.
Normal Operation
The compressor activates and water begins to fill the chiller tank at the
prescribed rate. When the water is chilled to 10ºC the Blue LED on the
Tap Head assembly stops flashing and stays illuminated. The compressor
continues to chill down to 5º when it will cycle Off.
Ensure that the clock matches your local time. If not refer to page 11 . If
Energy Saver Settings are required, the instructions for installing these are
described on page 11 “Setting the Energy Saver Timer”.
Chilled Water Lever
White Light
Blue Light
Filter Status Chilled
Use these buttons to
scroll through the menu
Use these buttons to
activate and de-activate
the program selected
CHILLED
DCHILLED