background image

Zip Hydro Tap Installation and Operating Instructions - 81759 - February 2013 v2.01 

Page 9 of 16

The Zenith HydroTap notifies when filter replacement is due. The default 
setting is 6000 Ltrs, but this can be set in increments of 1000Ltr from 1000Ltr 
to 10000Ltrs. When a filter change is due, the Change Filter light will flash 
white once a minute and remain so until reset. A filter status light is located 
between the Red and Blue Lights on the tap head assembly. 

Depending on local water quality conditions and usage, the filter may require 
changing anywhere from 1000 Ltrs to 10000 Ltrs. You may also need to 
replace the filter if you notice unpleasant odours or tastes.

Some water may drip from the filter head (socket) during replacement. Keep a 
towel handy to dry up any drips.

To change the Filter:

1.  Scroll through the screen menu to “Filter Flush Off” this isolates the water 

supply.

2.   Open the left door or on the compact model, remove the front cover by 

lifting the locking tab as shown in photo along side and lift off to expose 
the filter.

3.  Relieve system pressure via the filter flush stop cock, a quick open and 

close will do. Use the bucket to catch the discharge.

4.  Grasp filter cartridge, depress the red lever and rotate the cartridge a 

quarter turn to the left and gently pull down. 

Caution:  

a small amount of 

water will drip as the cartridge is removed. 

5.  Do not tilt the cartridge as water may spill from it if tilted.

6.  Unpack replacement cartridge, remove sanitary cap and write today’s date 

where shown on the label. 

7.  Avoid touching the filter O-rings and filter opening as this may cause 

bacterial contamination of the cartridge.

8.  Moisten the O-rings with water, align the front cartridge label to the left (as 

shown in the “insert filter” diagram for filter cartridge replacement), and 
push the new cartridge into the filter head. 

9.  Turn the cartridge a quarter turn to the right until the cartridge comes 

to complete stop and is locked into position, with the front label facing 
forward. 

10. Locate the filter flush hose situated behind the filter cartridge and direct 

the hose into a container ready for flushing. Open the filter flush stop-cock. 
On the control panel press adjust 

>

, this will start the water flow, flushing 

the cartridge. Allow at least 12 litres of water through the cartridge before 
use, to activate the filter. Isolate the filter flush stop-cock and re-fit behind 
the filter cartridge. Now press the adjust 

>

 to stop the flow. (It may take 

approximately 3 minutes to flush the 12 litres.)

11. Wipe up any spills and dispose of spent filter cartridge and packaging 

thoughtfully.

12. Scroll through the menu to “Litres Filtered”, press adjust 

>

 to reset litre 

counter. Press adjust 

>

 and it asks “are you sure”. Press adjust 

>

 again 

to lock in the command. 

13. Scroll through the menu to “Filter Used (Days)”, press adjust 

>

 to reset 

the timer. Press adjust 

>

 and it asks “are you sure”. Press adjust 

>

 again 

to lock in the command. After approx 10 seconds it will default to the 
selected mode.

14. Close the door to secure the appliance. 

Replacing the Filter

Warning: If the Zip HydroTap is 
switched off for a long period of 
time    (e.g. more than a weekend), 
run water through the chilled water 
outlet for at least 5 minutes before 
consumption.

FILTER CARTRIDGE REPLACEMENT

REMOVE FILTER

INSERT FILTER

Summary of Contents for HydroTap series

Page 1: ...ing Instructions 81759 February 2013 v2 01 Page 1 of 16 Zip HydroTap Filtered chilled drinking water for kitchens and tea rooms Installation and Operating Instructions Affix Model Number Label Here 81759 GP HydroTap Disabled lever HydroTap ...

Page 2: ...p C Connecting the tap 6 Step D Connecting the Water Supply 7 Step E Testing and commissioning 7 Font Installation procedure 8 Operating the Tap 8 Replacing the Filter 9 Setting the Energy Saver Timer 10 AuxillIiary Fan Attachment 11 Set Cold water dispensing Time 11 Trouble Shooting 12 End of Life Disposal 12 Cleaning 12 Exploded view Chiller Module and Spares 13 Notes 14 Contact Details 16 NOTE ...

Page 3: ... ensure adequate ventilation Make sure that the ventilation grilles of the undersink unit are not obstructed Included in the installation pack are adhesive backed silicon buffers If air vents are not installed in the cupboards housing the HydroTap the buffers must be placed on the inside edge of the cupboard door to create a slight gap ensuring a minimum airflow Failure to do this may cause the Hy...

Page 4: ...hin reach of the 750 mm flexible connection and positioned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed Power supply 220 240 Volt AC for connection to the heater via a 10 amp G P O Frost Protection If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not in use do not turn off the applia...

Page 5: ...nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more than 900mm above the base of the HydroTap unit Failure to do this may result in poor water delivery NOTE 2 Under no circumstances should the Tap be twisted after the installation is complete Installati...

Page 6: ... to accommodate the air vent provided Make sure that the undersink unit ventilation grilles are not obstructed in any way Step C Connecting the tap Measure and trim the blue tube and connect it to the chilled water outlet located on the top front right hand side of the undersink unit Use spring clamps provided Measure and trim the unmarked tube and connect it to the vent outlet NOTE All tubes must...

Page 7: ...nd the flush line stop cock Place the free end of the flush line into the bucket or container not supplied The display will show Filter Flush Mode Open the flush line stop cock To activate press adjust Run at least 7 5 Ltrs of water through to activate the filter membrane Press the adjust button again to stop the Filter Flush Mode Turn OFF the Filter Flush stop cock and re locate the tube and stop...

Page 8: ...spense chilled water in the temperature range 5 C to 10 C During heavy usage the temperature can rise out of this range Filter Change Light Off This indicates the filter is operating within its normal specified lifespan Filter Change Light Flashing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the filter section of ...

Page 9: ...ing the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 8 Moisten the O rings with water align the front cartridge label to the left as shown in the insert filter diagram for filter cartridge replacement and push the new cartridge into the filter head 9 Turn the cartridge a quarter turn to the right until the cartridge comes to complete stop and is lock...

Page 10: ...ions section of this document Press either Mode or Mode button until Litres Filtered is displayed Press Adjust once and Reset Counter will be displayed press Adjust button once and Are You Sure will be displayed Press Adjust once and Litres Filtered will be reset to 0 Activating On Off Mode Press the Mode or Mode button until Monday On is displayed To set the time for the unit to turn on press Adj...

Page 11: ...tion of the HydroTap The fan can be installed so that it extracts air from or forces air into the cupboard space whichever is the most effective for your installation Application of the fan is of paramount importance in situations where the cupboard space reaches temperatures greater than 35ºC The exhaust fan kit must be fitted when supplied with the appliance Tap Control Loom connections Set the ...

Page 12: ...itch is turned ON Check loom connection Contact local Zip Service Provider Check LCD for information Check water supply is on Check to ensure plumbing connection is made Check power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check LCD for information Check filter usage on LCD screen if filter change is displayed follow instructions...

Page 13: ...6 LOOM SOLENOID KIT 12 90626 CONTROL PANEL KIT 13 90628 STOP VALVE JOHN GUEST FITTING KIT FILTER 14 90056 FLEXIBLE BRAIDED HOSE KIT 15 90635 LEVEL SENSOR KIT COLD TANK 16 90636 RELAY COMPRESSOR KIT ITEM KIT NO DESCRIPTION 17 90637 COMPRESSOR KIT 18 90639 FAN MOTOR KIT 19 90437 CAPACITOR KIT 20 90185 LOOM LEVEL SENSOR KIT 21 90718 TRANSFORMER KIT AUXILLARY FAN 22 90190 LOOM GLAND MAIN PCB to TAP 23...

Page 14: ...Page 14 of 16 Zip Hydro Tap Installation and Operating Instructions 81759 February 2013 v2 01 Notes ...

Page 15: ...Zip Hydro Tap Installation and Operating Instructions 81759 February 2013 v2 01 Page 15 of 16 Notes ...

Page 16: ...65848 US4354049 US5103859 and US5099825 Other patents are in force and patent applications are pending Head Office Zip Heaters Aust Pty Ltd ABN 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia Website www zipheaters com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 As Zip policy is one of continuous product improvement c...

Reviews: