SECTION 11 HOME MENU ICONS

Safety switch is enabled.

 

The HydroTap

 

G4 will not dispense any Boiling water.

See tap sections for safety lock operation.

Safety switch is disabled. 

Boiling water may be dispensed. See tap sections for safety lock 

operation.

Sleep mode is active.

There are 7 sleep mode options which display this icon on the home 

screen. See page 25

 

for details.

Heater is in off mode.

 

When this icon is displayed, no power is being supplied to the 

heating element. See page 25 for Energy Mode options.

Filter use

This icon displays the filter usage remaining from 100% (new filter) 

to 0% (end of life). When it reaches 0% the filter warning light on the 

tap head will flash slowly. The filter life can be adjusted by litres and 

by days used.  

50%

Boiling temperature

The temperature of the water in the boiling tank will be displayed. 

This is optimises at 98°C but may be adjusted between 68°C- 98°C. 

See page 23 for hot set point adjustment.

Chilled temperature 

The temperature of the water in the chilled tank will be displayed, 

dependant upon model purchased.

SECTION 12 CLEANING

Do not use strong, corrosive spray or abrasive cleaners / chemicals. 

Clean the casing, tapware, external filter, piping and all other fittings with a 

soft cloth and mild soap and water. 

Do not spray water over the tap as it may damage the low-voltage electronics.

Caution: Should any of the plastic fittings accidentally come into contact 

with cleaners with a PH level less than 4, hypochlorite, hydrogen peroxide 

or any other aggressive chemical the affected component must be replaced 

immediately.

Command Centre units must never be located near, or cleaned with water 

jets. Avoid using airborne pesticides near the Command Centre.

Summary of Contents for HydroTap G4 Series

Page 1: ...MODEL NUMBER All G4 systems ZIPHYDROTAP G4 USER MANUAL Pure tasting boiling chilled sparkling water Instantly...

Page 2: ...n 2 HydroTap functionality 4 Section 3 Elite HydroTap 4 Section 4 Classic HydroTap 7 Section 5 Arc Cube HydroTap inc AIO Celsius Arc 10 Section 6 Celsius HydroTap 13 Section 7 Mixer taps 14 Section 8...

Page 3: ...SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK SECTION 1 HYDROTAP CONTROL STYLES Elite Touch controls See page 4 Classic Press pull controls See page 7 Celsius Rotate controls See page 13 All in One C...

Page 4: ...Chilled C All models ON Water at set temp FLASHING SLOWLY Water below set temp wait FLASHING QUICKLY System fault see page 17 BOILING TEMP CHILLED TEMP ON Water at set temp FLASHING SLOWLY Water abov...

Page 5: ...to dispense BC models touch to dispense BCS models touch to dispense B models touch to dispense C models Boiling water Chilled water Sparkling water both Boiling water Chilled water Boiling water Ambi...

Page 6: ...E WWW ZIPWATER CO UK CS models touch to dispense SECTION 3 ELITE HYDROTAP Chilled water BCS BC BA B models touch to dispense Boiling water Activate deactivate the safety lock see page 27 Either Sparkl...

Page 7: ...P CHILLED TEMP ON Water at set temp FLASHING SLOWLY Water above set temp wait FLASHING QUICKLY System fault see page 17 OFF Filter within life span FLASHING SLOWLY Change filter see pages 19 28 Filter...

Page 8: ...se Boiling water Chilled water BC models press to dispense Boiling water Chilled water BA models press to dispense Boiling water Ambient water C models press to dispense Chilled water either B models...

Page 9: ...ROTAP SAFETY LOCK 4 5 CLASSIC HYDROTAP SAFETY SENSOR Pull both levers forward Safety sensor Shield the HydroTapG4 from any direct sunlight With the Command Centre in normal operating mode and safety l...

Page 10: ...t set temp FLASHING SLOWLY Water below set temp wait FLASHING QUICKLY continuous System fault see page 17 FLASHING QUICKLY for 2 secs Ready to dispense boiling water with safety lock on CHILLED TEMP O...

Page 11: ...n turn to dispense Boiling water Chilled water Sparkling water BC models select then turn to dispense Boiling water Chilled water BA models select then turn to dispense Boiling water Ambient water C m...

Page 12: ...se Chilled water BCS BC BA B models 4 steps to dispense boiling water Flash for 2 secs Activate deactivate the safety lock see page 27 Sparkling water Boiling water mode with safety lock on 1 2 Touch...

Page 13: ...ASHING SLOWLY Water above set temp wait FLASHING QUICKLY System fault see page 17 FLASHING EVERY 10 SEC Change filter see pages 19 28 Indicator Warning FILTER 6 2 CELSIUS HYDROTAP LIGHTS The Indicator...

Page 14: ...ds the tap will decrease the flow When the lever is moved in the direction of the blue dot the temperature is decreased and when moved in the direction of the red dot the temperature is increased The...

Page 15: ...or more system faults Refer to section 8 2 System info Sleep Mode System is in sleep mode Neither boiling or chilled water are available Refer to section 8 7 Energy modes Change Filter External Intern...

Page 16: ...er flush Filter reset Boiling calibration Booster CO2 Purge Lux sensor calibration Advanced options Start Stop Internal External Calibration options Enable Disable 8 3 Service Password protected 8 4 S...

Page 17: ...een Press Filter Log to check the filter resets Press button for the previous menu or press HOME button to return to the home screen Press the MENU button for main menu Press the Info button to review...

Page 18: ...menu Press the Install button Turn the stop cock on Press the Filter Flush button Press START button to start filter flush Once the filter flush is finished turn the stop cock off first ensure the co...

Page 19: ...button for main menu Press the Install button Press the Boost button In the next screen press button A to enable the booster dispense boiling water for 30 seconds and check the insulated outlet hose...

Page 20: ...of the Lux sensor can be verified by selecting Lux Sensor OFF When the room is subsequently darkened below the calibrated light level the lights will turn off after approx 30 seconds SECTION 8 LCD SCR...

Page 21: ...ectrician plumber or call Zip on 0345 6 005 005 for assistance service spare parts or enquiries Fan speed adjustment If the Command Centreis operating near 35O C or higher then the fan speed must be 1...

Page 22: ...n Press Disable Press button for the previous menu 8 5 Security The Zip HydroTap G4 allows the appliance coordinator to set up a password to protect against users changing the preferred system setting...

Page 23: ...ressing the square button The selected mode will be displayed in dark grey colour with a tick box on the right Press NEXT button to set time 8 7 1 Set Date Time Press the MENU button for main menu Pre...

Page 24: ...aximum of 10000 litres Factory set at 6000 litres To edit the filter usage This function is to reset the filter change display after a filter has reached the end of its life see page 28 Filter mainten...

Page 25: ...Sensor 680 C Dark N A Sleep 680 C ON Lux Sensor OFF Dark N A OFF OFF OFF Lux Sensor or 2 Hr 680 C Dark 2 Hr Sleep 680 C ON Lux Sensor or 2 Hr OFF Dark 2 Hr OFF OFF OFF Disable N A N A ON ON ON In slee...

Page 26: ...at a specific time To activate On Off mode Press the MENU button for main menu Press the Settings button Enter your 4 digit password and press Enter Press the Energy Modes button Press the On Off Mod...

Page 27: ...d with a safety mode that allows for additional safety protection if needed Hot isolation To allow safety changes select YES on the safety settings screen To activate press button to disable safety lo...

Page 28: ...filter replacement is due If you notice one of the following you will need to change the filter The white change filter light will flash and remain so until reset The filter percentage will show 0 on...

Page 29: ...lockwise until it comes to a complete stop and locks with the front label facing forward Initiate the filter flush programme by scrolling through the menu screen see page 18 When completed clean up an...

Page 30: ...op securing strap Turn the regulator on turn regulator knob anti clockwise to end stop Check all joints for gas leaks using a sponge and soapy water Purge the gas lines see CO2 purge page 20 Note When...

Page 31: ...adjusted by litres and by days used 50 Boiling temperature The temperature of the water in the boiling tank will be displayed This is optimises at 98 C but may be adjusted between 68 C 98 C See page...

Page 32: ...Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005 sales zipindustries co uk www zipwater co uk...

Reviews: