19
18
USER MANUAL
805846UK - ZIP HYDROTAP G4 V1.00 NOV 2017
TECHNICAL SUPPORT
TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
SECTION 8 LCD SCREEN
•
Press the [MENU] button for main
menu.
•
Press the [Install] button.
•
Press the [Filter Reset] button.
•
Press the [Reset Internal Filter] /
[Reset External Filter] button.
•
If you need to flush the filter follow
the filter flush guide, see page 18.
•
To cancel the filter reset program
press [HOME] or [<=].
•
To set the filter life or edit filter
usage, see page 24.
After replacing the filter, the counters should be reset.
•
Press the [MENU] button for main
menu.
•
Press the [Install] button.
•
Press the [Boiling Calibration]
button.
•
In the next screen, press
[Calibrate] if you want to start
calibration.
8.3.3 Boiling calibration
(boiling models only)
•
Press the [MENU] button for main
menu.
•
Press the [Install] button.
•
Press the [Boost] button.
•
In the next screen, press button
A to enable the booster,
dispense boiling water for 30
seconds and check the (insulated)
outlet hose from the booster is
warm.
This function should only be used when a booster unit is installed.
8.3.4 Booster
(boiling models only)
Note
Failing to make the correct selection for [Boost] will affect product
performance.
8.3.2 Filter reset
Caution
In general, boiling water units may vent steam from the tap spout.
Take care to avoid personal injury whenever this occurs.
The Zip HydroTap
G4 is equipped with a self-calibrating program. On start
up, the controls take the system through a calibration process. Once this
mode is completed the system reverts back to normal operation. If you would
like to calibrate the system anytime after installed, please follow the steps
below.
A
!
Refer to the Command Centre
instructions if
installing a Booster.