SECTION 9 FILTER MAINTENANCE
Warning: If the
HydroTap
G4 is switched
off for a long period of
time (e.g. more than a
weekend), run water through the
chilled water outlet for at least 5
minutes before consumption.
•
Caution
Water will drip as the cartridge is removed.
•
Do not tilt the cartridge as water may spill from it if tilted.
•
Unpack replacement cartridge and remove sanitary cap, write
today’s date where shown on the label.
•
Avoid touching the filter o-rings and filter opening as this may cause
bacterial contamination of the cartridge.
•
Moisten the o-rings with water, align the front cartridge label to the
left (as shown in the “insert filter” diagram below), and push the new
cartridge up into the filter head.
•
Turn the cartridge a quarter turn anticlockwise until it comes to a
complete stop and locks, with the front label facing forward.
•
Initiate the filter flush programme by scrolling through the menu screen
(see page 18).
•
When completed, clean up and dispose of old cartridge and packaging.
•
Close the door to secure the appliance.
•
Adjust the filter settings (see page 24) litres and days.
!
The HydroTap
G4 air filter is conveniently located on the outside of the
condenser. The filter screen is a sliding fit in the plastic housing on the
left hands side of the Command Centre. The screen may be removed for
cleaning by sliding it forward. This needs to be inspected at least quarterly,
cleaned and replaced if damaged.
Note
For best performance the unit should only be operated with a clean
air filter screen, correctly fitted in place. Maintain at least a 50mm air gap
in front of the screen at all times. Take care not to allow cloths or other soft
materials to accidentally block the air inlet.
Slide to
remove
Rotate
Pull
Remove filter
Insert filter
Rotate
Insert
9.3 Air inlet filter change
!