SECTION 8 LCD SCREEN
8.7.4 Energy modes
This mode allows the HydroTap
G4 to go into energy saving mode. There are
two options available: sleep mode and on/off mode.
It is recommended to recalibrate the lux sensor after selecting any of the
lux sensor options from the sleep mode menu. (See page 20 ,Lux sensor
calibration).(Classic, Arc / Cube only).
Sleep Mode*
Light
level
Time
delay
State
Boiler
Chiller
2 Hours > 68
0
C
N/A
2 Hr
Sleep
68
0
C
ON
2 Hours > OFF
N/A
2 Hr
OFF
OFF
OFF
Lux Sensor > 68
0
C
Dark
N/A
Sleep
68
0
C
ON
Lux Sensor > OFF
Dark
N/A
OFF
OFF
OFF
Lux Sensor or 2 Hr > 68
0
C
Dark
2 Hr
Sleep
68
0
C
ON
Lux Sensor or 2 Hr > OFF
Dark
2 Hr
OFF
OFF
OFF
Disable
N/A
N/A
ON
ON
ON
In sleep mode the unit will go to “Sleep” after a 2hr period of inactivity. The
boiling water will gradually drop to either 68°C or room temp, as shown in the
table below and the chilled water will be ON or OFF.
•
Press the [MENU] button for main
menu.
•
Press the [Settings] button.
•
Enter your 4-digit password and
press [Enter].
•
Press the [Energy Modes] button.
•
Press the [Sleep Modes] button
then in the next screen, use the
up and down arrow to select sleep
mode from the 7 options in the
table below.
To activate sleep mode