Page 16 of 40
802005UK - Residential (Boiling),chilled and sparkling installation instructions - Aug 2015 - v2.01
1.10
Braided
hose x 3
Mixer tap installation
1.11
Nut
Lower rubber
washer
Upper rubber washer
Washer
Nut
Lower rubber
washer
Upper rubber washer
Washer
White marking - Ambient
mains supply
Blue marking - MIXER IN
on Command-Centre
TM
Red marking - MIXER OUT
on Command-Centre
TM
Note
Make sure the tap location will allow the tap
spout to drain into the sink.
Note
The mixer tap requires a Restrictaflow valve,
supplied, to be fitted in the cold water supply line,
from the isolation valve T-piece, to the mixer tap
(see page 30).
•
Slide upper rubber washer in place on underside
of tap.
•
Mount tap in position on
Ø
35mm hole.
•
Slide lower rubber washer, metal washer then
tap nut over thread extension, then tighten the
tap nut to secure in place, do not over tighten.
•
Attach the braided hoses (ensure the seals on
the end of the hoses are lubricated), do not over
tighten.
Cut a
Ø
35mm hole in the worktop / sink.
Ø
35mm
Clearance
envelope
535mm
min. 300mm
(See page 30 for Command-Centre
TM
connections).
335mm