Connecting the Tap continued
Models ABA and ABB
Measure and trim the red marked tube and connect it to the hot water
outlet on the top of the undersink unit.
Measure and trim the unmarked tube and connect it to the vent outlet on
the top of the undersink unit.
For ABA only, measure and trim the blue marked tube and connect to the
ambient water outlet on the top of the undersink unit..
Connect the tap electrical connector to the cord attached to the undersink
unit. Align the pins carefully and do not force the plug. Clamp the cable to
the wall with clips provided so that the plug hangs vertically.
Model B
Measure and trim the red marked tube and connect it to the hot water
outlet on the top of the undersink unit.
Measure and trim the unmarked tube and connect it to the vent outlet on
the top of the undersink unit.
Connect the tap electrical connector to the cord attached to the undersink
unit. Align the pins carefully and do not force the plug. Clamp the cable to
the wall with clips provided so that the plug hangs vertically.
Note:
In some circumstances, steam and/or boiling water may discharge
from the vent at the rear of the tap shank. If the tap is not installed
on a sink, the pipe to this vent must be removed from the spigot at
the base of the tap and plumbed away to a safe location in
accordance with local plumbing regulations