Zip HydroTap Installation and Operating Instructions - 82872 - July 2003
Page 5 of 20
#
Section Heading
These Installation Instructions cover the entire Zip HydroTap range. Use the
chart on the left to identify the model you are using:
Model:
ABC = Filtered, boiling and chilled, timer
ABA = Filtered, boiling and ambient
ABB = Filtered, boiling only
B = Boiling only (unfiltered)
Boiling Water Capacity:
10 = 10 cups 30 = 30 cups
Chilled Water Capacity: (ABC only)
30 = 30 cups
Filtration: (ABA, ABB and ABC only)
FX = Sub micron filter
Models covered by these instructions
Before installing ensure that the following have been provided at the
installation site:
•
Sufficient space in the cupboard to install the undersink unit in
accordance with these Installation Instructions. A table of dimensions is
given below.
•
A water supply connection with isolating valve inside the cupboard
within reach of the 750 mm flexible connection and positioned so that
the connection point and the stop cock will not be obstructed when the
undersink unit is installed.
•
A water supply which can deliver 2 litres per minute flow rate at
minimum of 1.5 Bar (150 kPa) flow (dynamic) pressure.
•
Power supply connection to the heater via a double pole fused spur with a
minimum break rating of 13 amps.
•
Cold water supply with a minimum working pressure of 1.5 bar (150 kPa)
and a maximum working pressure of 10 bar (1000 kPa) connected via an
isolation valve.
Important:
Do not proceed with the installation if these requirements are not met.
Capacity 10/30
Height Depth
Width
Weight
kg/(lb)
mm (in.)
mm (in.)
mm (in.)
Empty
Full
ABC
340 (13.4)
510 (20)
340 (13.4)
30 (66.1)
36 (79.3)
ABA and ABB
343 (13.5)
343 (13.5)
287 (11.3)
14 (30.8)
16 (35.2)
B
340 (13.9)
277 (10.9)
194 (7.6)
12 (26.4)
14 (30.8)
Capacity 30/30
Height Depth
Width
Weight
kg/(lb)
mm (in.)
mm (in.)
mm (in.)
Empty
Full
ABC
383 (15)
510 (20)
477 (18.8)
32 (70.5)
42 (90.3)
ABA and ABB
383 (15)
433 (17)
340 (13.4)
18 (39.7)
23 (50.7)
B
380 (15)
369 (14.5)
284 (11.2)
16 (35.2)
21 (46.2)
Installation Requirements
ABC
Model
10/
Boiling
Water
Capacity
30
Chilled
Water
Capacity
FX
Filtration