Step B - Installing the undersink unit (all models)

Before positioning heater connect the braided water inlet hose (supplied) to
cold water inlet on unit. This is located on the left hand side.

Position the Zip HydroTap undersink unit as closely as possible to directly
beneath the Zip HydroTap tap head.

The connection tubes supplied with the tap head assembly CANNOT be
lengthened.

Leave at least a 50 mm air-gap without obstruction on each side of the
unit.

Fasten the fixing brackets (located behind the access door) to the cupboard
floor using screws provided.

Adjust both cupboard door hinges and attach the supplied rubber door
buffers to the doors to create a 4 mm air-gap between the doors and the
cupboard. This is the minimum ventilation requirement.

Caution:

Proper air circulation must be provided. The system will operate

correctly only if the recommended air gaps are achieved during installation.
If this is not possible, ventilation slots must be cut into the top AND bottom
of the cupboard door. Make sure that ventilation grilles are not obstructed.

Allow access to water inlet located on the left hand side of undersink unit.

Step C - Connecting the tap

Model ABC

Mount the External Chilled Water Expansion Chamber (ECWEC) into the cold
water outlet on the top of the undersink unit by pressing down firmly into
the John Guest fitting.

Measure and trim the blue tube and connect it to the top centre outlet of
the ECWEC.

Measure and trim the small tube and connect it to the offset outlet on the
top of the ECWEC.

Measure and trim the red marked tube and connect it to the hot water
outlet on the top of the undersink unit.

Measure and trim the unmarked tube and connect it to the vent outlet on
the top of the undersink unit

Connect the tap electrical connector to the cord attached to the undersink
unit. Align the pins carefully and do not force the plug. Clamp the cable to
the wall with clip provided so that the plug hangs vertically.

Note: 

When trimming any silicon tubes trim to minimum length, do not
loop the excess or allow kink of the tubes. When connecting, slide
the tube over the pipe at least 25 mm.

Installation procedure continued

Boiling
Water (red)

Vent

Chilled
Water
(blue)

Vent

ECWEC

Electrical

4 mm

+50 mm

+50 mm

Summary of Contents for HydroTap ABC10/30FXC

Page 1: ...73078 Zip HydroTap ABC10 30FXC 73119 Zip HydroTap ABC30 30FXC 73081 Zip HydroTap ABA10FXC 73123 Zip HydroTap ABA30FXC 73118 Zip HydroTap ABB10FXC 73121 Zip HydroTap ABB30FXC 73110 Zip HydroTap B1OC 7...

Page 2: ...Page 2 of 20 Zip HydroTap Installation and Operating Instructions 82872 July 2003...

Page 3: ...lling the undersink unit all models 7 Step C Connecting the tap 7 Installation with Tap Font 8 Tap Font Mounting Template a d Installation procedure Continued 13 Step C Connecting The Tap continued 13...

Page 4: ...he Zip HydroTap undersink unit Some units may exceed safe lifting limits Do not lift without assistance The weights of the units are given in the table under Installation Requirements page 5 Airflow P...

Page 5: ...ned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed A water supply which can deliver 2 litres per minute flow rate at minimum of 1 5 Bar 150...

Page 6: ...that the tap will be able to drain into the sink Mark the two hole centres and cut the small hole using a 13 5 mm sheet metal hole punch Cut the large hole using a 35 mm sheet metal hole punch Install...

Page 7: ...bottom of the cupboard door Make sure that ventilation grilles are not obstructed Allow access to water inlet located on the left hand side of undersink unit Step C Connecting the tap Model ABC Mount...

Page 8: ...pedestal is positioned above largest hole in bench Pass all cables and tubes from pedestal through largest hole in bench Fit clamp spacer and lock nut on to drain bush and tighten securely Clean off...

Page 9: ...Zip HydroTap Installation and Operating Instructions 82872 July 2003 Page a Detach this papertemplate and use it to position your Zip Hydrotap Tap Font on your kitchen bench...

Page 10: ...80 mm 45 mm MINIMUM CLEARANCE FROM REAR WALL CIRCUMFERENCE OF TAP FONT BASE SMALL HOLE SCREW HOLE SCREW HOLE...

Page 11: ...57 mm SCREW HOLE SCREW HOLE LARGE HOLE...

Page 12: ...Page d Zip HydroTap Installation and Operating Instructions 82872 July 2003 Detach this paper template and use it to position your Zip Hydrotap Tap Font on your kitchen bench...

Page 13: ...gs vertically Model B Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit Measure and trim the unmarked tube and connect it to the vent outlet...

Page 14: ...the Fill switch to the On down position The water will stop flowing For Model ABC press and hold the blue button for about 1 minute after water begins to flow Check that the lamps operate according t...

Page 15: ...provider The red lamp flashes once a second There is a problem with the Turn off the power and the water when the water is hot undersink unit and call your Zip service provider The boiling water is ru...

Page 16: ...s a leak in the undersink water system and the unit will be shut down In this case call Zip services Filter Change Light Flashing slowly once every minute The light will flash once every minute when t...

Page 17: ...ch it from the filter head socket 4 Do not tilt the cartridge as dirty water may spill from it if tilted 5 Unpack replacement cartridge and write today s date where shown on the label 6 Avoid bacteria...

Page 18: ...selected Press and release button m until correct minute is selected When day hour and minute are correct release button Programming Power ON OFF 1 Press and release the Prog button once 2 Display wil...

Page 19: ...returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance or consequential damage to any other goods furnishings or property No w...

Page 20: ...gistered trade marks Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 and US509...

Reviews: