Page 8 of 20
Zip HydroTap Installation and Operating Instructions - 82872 - July 2003
Installation with Tap Font
Features
The sump built into the Tap-Font drains away to any nearby waste.
Also elevates tap outlet to provide 210 mm clearance for pots.
Positioning
Position Tap-Font as close as possible to directly above under-sink unit.
Never extend either the cable or tubing attached to the head assembly.
If possible position tray on bench so the tap is to the rear, then rotate base
45 degrees anti-clockwise.
Drilling
Use paper template to drill 57 mm hole, 45 mm hole and 4 screw holes.
For timber bench, drill 3 mm screw holes for timber screws provided.
For granite or similar, drill 6 mm holes for stainless screws provided.
Assembling
Fix clamp plate to bench top using 4 "timber" or "stainless" screws
provided.
Remove silicon vent tube from base of tap assembly as shown in diagram.
Pass electrical cable, then tubes, from tap base through pedestal as shown.
Check cable and tubes to ensure all are free, none are twisted or kinked.
Fix the tap head assembly to pedestal using 3 pedestal screws.
Apply sealant to thread on brass tube supplied, screw into pedestal base.
Attach disconnected silicon vent tube to brass vent tube as shown in photo.
Apply a light bead of sealant to the underside edge of the sump tray.
Position the tray so the sump drain outlet lines up with the fixing plate hole.
Swivel tray so pedestal is positioned above largest hole in bench.
Pass all cables and tubes from pedestal through largest hole in bench.
Fit clamp spacer and lock nut on to drain bush and tighten securely.
Clean off any sealant squeezed out around sump tray during clamping.
Connecting
Install the waste clamp in an accessible position on the "sink side" of drain
trap and as high as possible above the trap water line.
The waste clamp must never be installed on the "drain side" of drain trap.
To drill access hole into trap, remove nut and olive from clamp fitting and
select drill bit to fit inside diameter of the clamp fitting hole.
Fasten clamp to drain pipe and drill access hole through hole in clamp.
Apply sealant to thread on brass tube supplied and fasten tube to clamp
with nut and olive, referred to above.
Apply sealant to similar brass tube and fit to drain bush on sump.
Connect tube on clamp to tube on sump using flexible tubing provided.
Ensure flexible tube has a continuous fall from sump to clamp.
Remove protective coating from stainless steel, wipe clean and fit
removable drip plate. Fit remaining tubes and cable as shown on page 7.
Inserting screw through pedestal
to underside of tap.
An alternative to mounting the Zip
HydroTap tap head on a sink.
Use Zip HydroTap Tap-Font kit to install
tap anywhere on bench.
To order Tap-Font kit, quote Zip part
number 99057.
Tap Assembly
Remove
Flexible
vent Tube
Vent Pipe
Drip Plate
Brass Outlet
Tube
Clamp
Spacer
Tap
Assembly
Waste
Clamp
Brass Drain
Tube
Clamp Plate
Bench Top
Flexible
Drain Tube
Lock Nut
Drain Tube
Sump
Sump Tray
Pedestal Screws
Pedastal