Zip HydroTap Installation and Operating Instructions - 82872 - July 2003

Installation with Tap Font

Features

The sump built into the Tap-Font drains away to any nearby waste.

Also elevates tap outlet to provide 210 mm clearance for pots.

Positioning

Position Tap-Font as close as possible to directly above under-sink unit.

Never extend either the cable or tubing attached to the head assembly.

If possible position tray on bench so the tap is to the rear, then rotate base
45 degrees anti-clockwise.

Drilling

Use paper template to drill 57 mm hole, 45 mm hole and 4 screw holes.

For timber bench, drill 3 mm screw holes for timber screws provided.

For granite or similar, drill 6 mm holes for stainless screws provided.

Assembling

Fix clamp plate to bench top using 4 "timber" or "stainless" screws
provided.

Remove silicon vent tube from base of tap assembly as shown in diagram.

Pass electrical cable, then tubes, from tap base through pedestal as shown.

Check cable and tubes to ensure all are free, none are twisted or kinked.

Fix the tap head assembly to pedestal using 3 pedestal screws.

Apply sealant to thread on brass tube supplied, screw into pedestal base.

Attach disconnected silicon vent tube to brass vent tube as shown in photo.

Apply a light bead of sealant to the underside edge of the sump tray.

Position the tray so the sump drain outlet lines up with the fixing plate hole.

Swivel tray so pedestal is positioned above largest hole in bench.

Pass all cables and tubes from pedestal through largest hole in bench.

Fit clamp spacer and lock nut on to drain bush and tighten securely.

Clean off any sealant squeezed out around sump tray during clamping.

Connecting

Install the waste clamp in an accessible position on the "sink side" of drain
trap and as high as possible above the trap water line.

The waste clamp must never be installed on the "drain side" of drain trap.

To drill access hole into trap, remove nut and olive from clamp fitting and
select drill bit to fit inside diameter of the clamp fitting hole.

Fasten clamp to drain pipe and drill access hole through hole in clamp.

Apply sealant to thread on brass tube supplied and fasten tube to clamp
with nut and olive, referred to above.

Apply sealant to similar brass tube and fit to drain bush on sump.

Connect tube on clamp to tube on sump using flexible tubing provided.

Ensure flexible tube has a continuous fall from sump to clamp.

Remove protective coating from stainless steel, wipe clean and fit
removable drip plate. Fit remaining tubes and cable as shown on page 7.

Inserting screw through pedestal

to underside of tap.

An alternative to mounting the Zip
HydroTap tap head on a sink.

Use Zip HydroTap Tap-Font kit to install
tap anywhere on bench.

To order Tap-Font kit, quote Zip part
number 99057.

Tap Assembly

Remove

Flexible

vent Tube

Vent Pipe

Drip Plate

Brass Outlet

Tube

Clamp

Spacer

Tap

Assembly

Waste

Clamp

Brass Drain

Tube

Clamp Plate

Bench Top

Flexible

Drain Tube

Lock Nut

Drain Tube

Sump

Sump Tray

Pedestal Screws

Pedastal

Summary of Contents for HydroTap ABC10/30FXC

Page 1: ...73078 Zip HydroTap ABC10 30FXC 73119 Zip HydroTap ABC30 30FXC 73081 Zip HydroTap ABA10FXC 73123 Zip HydroTap ABA30FXC 73118 Zip HydroTap ABB10FXC 73121 Zip HydroTap ABB30FXC 73110 Zip HydroTap B1OC 7...

Page 2: ...Page 2 of 20 Zip HydroTap Installation and Operating Instructions 82872 July 2003...

Page 3: ...lling the undersink unit all models 7 Step C Connecting the tap 7 Installation with Tap Font 8 Tap Font Mounting Template a d Installation procedure Continued 13 Step C Connecting The Tap continued 13...

Page 4: ...he Zip HydroTap undersink unit Some units may exceed safe lifting limits Do not lift without assistance The weights of the units are given in the table under Installation Requirements page 5 Airflow P...

Page 5: ...ned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed A water supply which can deliver 2 litres per minute flow rate at minimum of 1 5 Bar 150...

Page 6: ...that the tap will be able to drain into the sink Mark the two hole centres and cut the small hole using a 13 5 mm sheet metal hole punch Cut the large hole using a 35 mm sheet metal hole punch Install...

Page 7: ...bottom of the cupboard door Make sure that ventilation grilles are not obstructed Allow access to water inlet located on the left hand side of undersink unit Step C Connecting the tap Model ABC Mount...

Page 8: ...pedestal is positioned above largest hole in bench Pass all cables and tubes from pedestal through largest hole in bench Fit clamp spacer and lock nut on to drain bush and tighten securely Clean off...

Page 9: ...Zip HydroTap Installation and Operating Instructions 82872 July 2003 Page a Detach this papertemplate and use it to position your Zip Hydrotap Tap Font on your kitchen bench...

Page 10: ...80 mm 45 mm MINIMUM CLEARANCE FROM REAR WALL CIRCUMFERENCE OF TAP FONT BASE SMALL HOLE SCREW HOLE SCREW HOLE...

Page 11: ...57 mm SCREW HOLE SCREW HOLE LARGE HOLE...

Page 12: ...Page d Zip HydroTap Installation and Operating Instructions 82872 July 2003 Detach this paper template and use it to position your Zip Hydrotap Tap Font on your kitchen bench...

Page 13: ...gs vertically Model B Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit Measure and trim the unmarked tube and connect it to the vent outlet...

Page 14: ...the Fill switch to the On down position The water will stop flowing For Model ABC press and hold the blue button for about 1 minute after water begins to flow Check that the lamps operate according t...

Page 15: ...provider The red lamp flashes once a second There is a problem with the Turn off the power and the water when the water is hot undersink unit and call your Zip service provider The boiling water is ru...

Page 16: ...s a leak in the undersink water system and the unit will be shut down In this case call Zip services Filter Change Light Flashing slowly once every minute The light will flash once every minute when t...

Page 17: ...ch it from the filter head socket 4 Do not tilt the cartridge as dirty water may spill from it if tilted 5 Unpack replacement cartridge and write today s date where shown on the label 6 Avoid bacteria...

Page 18: ...selected Press and release button m until correct minute is selected When day hour and minute are correct release button Programming Power ON OFF 1 Press and release the Prog button once 2 Display wil...

Page 19: ...returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance or consequential damage to any other goods furnishings or property No w...

Page 20: ...gistered trade marks Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 and US509...

Reviews: