background image

Page 20 of 20

Zip HydroTap Installation and Operating Instructions - 82872 - July 2003

The standard cup referred to in this publication is 167 ml (6 fl oz).
The standard glass is 200 ml (7 fl oz).
The terms "Zip", "HydroTap" and "Hydroboil" are registered trade marks.
Zip products described in this publication are manufactured under one or more of the following
patents: AU675601, AU637412, AU635979, GB0422305, GB2065848, US4354049, US5103859,
and US5099825. Other patents are in force and patent applications are pending.

Zip Heaters (UK) Ltd
14/15 Bertie Ward Way
Rash’s Green Dereham
Norfolk NR19 1TE

www.zipheaters.co.uk

Telephone: 0870 608 8888
Facsimile: 01362 692448

Contact Details

Summary of Contents for HydroTap ABC10/30FXC

Page 1: ...73078 Zip HydroTap ABC10 30FXC 73119 Zip HydroTap ABC30 30FXC 73081 Zip HydroTap ABA10FXC 73123 Zip HydroTap ABA30FXC 73118 Zip HydroTap ABB10FXC 73121 Zip HydroTap ABB30FXC 73110 Zip HydroTap B1OC 7...

Page 2: ...Page 2 of 20 Zip HydroTap Installation and Operating Instructions 82872 July 2003...

Page 3: ...lling the undersink unit all models 7 Step C Connecting the tap 7 Installation with Tap Font 8 Tap Font Mounting Template a d Installation procedure Continued 13 Step C Connecting The Tap continued 13...

Page 4: ...he Zip HydroTap undersink unit Some units may exceed safe lifting limits Do not lift without assistance The weights of the units are given in the table under Installation Requirements page 5 Airflow P...

Page 5: ...ned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed A water supply which can deliver 2 litres per minute flow rate at minimum of 1 5 Bar 150...

Page 6: ...that the tap will be able to drain into the sink Mark the two hole centres and cut the small hole using a 13 5 mm sheet metal hole punch Cut the large hole using a 35 mm sheet metal hole punch Install...

Page 7: ...bottom of the cupboard door Make sure that ventilation grilles are not obstructed Allow access to water inlet located on the left hand side of undersink unit Step C Connecting the tap Model ABC Mount...

Page 8: ...pedestal is positioned above largest hole in bench Pass all cables and tubes from pedestal through largest hole in bench Fit clamp spacer and lock nut on to drain bush and tighten securely Clean off...

Page 9: ...Zip HydroTap Installation and Operating Instructions 82872 July 2003 Page a Detach this papertemplate and use it to position your Zip Hydrotap Tap Font on your kitchen bench...

Page 10: ...80 mm 45 mm MINIMUM CLEARANCE FROM REAR WALL CIRCUMFERENCE OF TAP FONT BASE SMALL HOLE SCREW HOLE SCREW HOLE...

Page 11: ...57 mm SCREW HOLE SCREW HOLE LARGE HOLE...

Page 12: ...Page d Zip HydroTap Installation and Operating Instructions 82872 July 2003 Detach this paper template and use it to position your Zip Hydrotap Tap Font on your kitchen bench...

Page 13: ...gs vertically Model B Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit Measure and trim the unmarked tube and connect it to the vent outlet...

Page 14: ...the Fill switch to the On down position The water will stop flowing For Model ABC press and hold the blue button for about 1 minute after water begins to flow Check that the lamps operate according t...

Page 15: ...provider The red lamp flashes once a second There is a problem with the Turn off the power and the water when the water is hot undersink unit and call your Zip service provider The boiling water is ru...

Page 16: ...s a leak in the undersink water system and the unit will be shut down In this case call Zip services Filter Change Light Flashing slowly once every minute The light will flash once every minute when t...

Page 17: ...ch it from the filter head socket 4 Do not tilt the cartridge as dirty water may spill from it if tilted 5 Unpack replacement cartridge and write today s date where shown on the label 6 Avoid bacteria...

Page 18: ...selected Press and release button m until correct minute is selected When day hour and minute are correct release button Programming Power ON OFF 1 Press and release the Prog button once 2 Display wil...

Page 19: ...returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance or consequential damage to any other goods furnishings or property No w...

Page 20: ...gistered trade marks Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 and US509...

Reviews: