7
Installation instructions & user manual
T210023 v1.02 NOV 2018 - ZIP AP430S-AP4100S
Technical support
Tel: 0345 6 005 005 email: service@zipindustries .co.uk www.zipwater.co.uk
the safety valve is not blocked.
• Do not install a stop valve between the water heater and the safety valve,
because it will impair the pressure protection of the Aquapoint.
• The Aquapoint
is equipped with an additional thermal cut-off for protection
in case of failure of the operating thermostat. In this case, however, the
temperature of the water in the heater can reach up to 130°C according to
the safety standards. During the water supply installation, the possibility of
temperature overloads should be taken into account.
• If the Aquapoint is to be disconnected from the power supply, please drain
any water from the heater to prevent freezing.
• Water from the Aquapoint that is installed vertically on the wall can be
drained through the heater’s inlet pipe. For this purpose it is advisable to
install a T- piece with an outlet valve between the inlet pipe and safety
valve.
•
Please do not try to fix any defects of the
Aquapoint on your own.
• Call Zip on 0345 6 005 005.
• The
Aquapoint must be completely filled with water before being switched
on.
CAUTIONS
• The Aquapoint must only be used when correctly installed and in perfect
working order.
• The
Aquapoint must be installed in a frost-free room and must never be
exposed to frost.
• The Aquapoint range is not recommended for use with secondary
circulation systems.
• The Aquapoint must only be used for heating potable water. The Aquapoint
must not be used for any other purpose.
• When
the Aquapoint has been in use for some time, the fittings may be
very hot.
• The Aquapoint is intended for connection to mains supply only. In any other
case please contact Zip on 0345 6 005 005 for advice.
• Zip Water UK cannot be held liable for any damages caused by failure to
observe these instructions.
SAFETY INFORMATION
!
!