Technical support 

 

Tel: 0345 6 005 005 email: service@zipindustries .co.uk  www.zipwater.co.uk

has been diagnosed and necessary repairs have been undertaken.

•  Do not use the Aquapoint if it is suspected of being frozen. Switch off the 

electrical

 

supply if water ceases to flow and do not switch on again until a 

competent person has checked that it is safe to do so.

•  The heater should be visually inspected regularly. This is particularly 

important if its located in a cupboard, roof space or any other concealed 

location. If there is any sign of leaks or seepage the Aquapoint should be 

isolated from the water supply and switched off from the electrical supply 

until a competent person has investigated the cause.

•  Do not block or restrict the discharge from any safety valve.

•  Do not tamper with any safety valve.

•  The Aquapoint must not be subjected to pressure exceeding 6 bar.

•  If water discharges from any safety valve switch off the electrical supply to 

the Aquapoint, isolate the water supply and contact a competent person 

familiar with unvented systems.

•  Temperatures in excess of approximately 43°C are perceived as hot, 

especially by children, and may cause a feeling of burning. Please consider 

using the temperature controls.

•  This Aquapoint must not be used by any person (inclu ding children) with 

limited physical, sensorial or mental abilities or failing experience and/or 

knowledge unless they are supervised by a person responsible for their 

safety or have received instruction about how to use the Aquapoint, and 

that are aware of the potential hazards.

•  Children should be supervised in order to make sure that they do not play with, 

use, clean or maintain the Aquapoint.

•  In a closed, pressurised system of installation, it is obligatory to install a 

safety valve on the inlet pipe with a rated pressure of 0.6 MPa (6 bar), 

0.9 MPa (9 bar) or 1.0 MPa (10 bar) (see the label), which prevents the 

elevation of pressure in the boiler by more than 0.1 MPa (1 bar) above the 

rated pressure.

•  Water may drip from the outlet opening of the safety valve, so the outlet 

opening should be set to atmospheric pressure.

•  The outlet of the safety valve should be installed facing downwards and in 

a non-freezing area.

•  To ensure proper functioning of the safety valve, the user should perform 

regular inspection and maintenance to remove lime scale and make sure 

SAFETY INFORMATION

Summary of Contents for Aquapoint AP430S SmartEco

Page 1: ...0023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Zip Aquapoint Installation instructions user manual Modelnumber AP430S...

Page 2: ...nstruction manual please visit www zipwater co uk to download the latest copy Please leave these instructions with the end user after installation General Product Description 3 Approvals 3 Technical D...

Page 3: ...ection for the vessel and the heating element Gradual erosion of the anode will occur depending on local conditions and in extreme cases conditions may cause rapid erosion resulting in particles being...

Page 4: ...564 49 740 Weekly electricity consumption without smart control kWh 16 215 28 501 30 049 57 832 Thermostat temperature setting eco Smart value 1 Storage volume V l 29 1 49 1 78 8 98 1 Mixed water at 4...

Page 5: ...ating suitable for the nomi nal current of the Aquapoint The cross sectional area of the connection cable must be appropriate for the power rating and location of the Aquapoint The connecting cable mu...

Page 6: ...unvented systems Temperatures in excess of approximately 43 C are perceived as hot especially by children and may cause a feeling of burning Please consider using the temperature controls This Aquapo...

Page 7: ...vertically on the wall can be drained through the heater s inlet pipe For this purpose it is advisable to install a T piece with an outlet valve between the inlet pipe and safety valve Please do not...

Page 8: ...ement 2000W 002 AQ0331 Gasket 005 94807 Bimetal safety cut out 006 AQ0320 Sacrifying anode 30 l 006 AQ0306 Sacrifying anode 50 l 006 AQ0307 Sacrifying anode 80 l 100 l 013 AQ0338 Fixing flange 019 950...

Page 9: ...rced where the Aquapoint will be installed The AP4 model may only be mounted vertically To facilitate future service interventions you are advised to install the heater in accordance with the installa...

Page 10: ...m Fig 4 pressurised mix taps should be used at the outlet points To ensure safe operation of the heater a safety valve should be installed on the inlet pipe to prevent elevation of pressure for more t...

Page 11: ...th the capacity of at least 5 of the heater volume To ensure proper operation of the safety valve periodical inspections must be carried out to remove limescale and make sure the safety valve is not b...

Page 12: ...xpansion vessel with wall bracket from cold inlet set take off 4 Hot water outlet 5 Temperature control 6 Neon indicator 7 Tundish to drain 8 Temperature and pressure relief valve 9 Expansion relief v...

Page 13: ...hrough a double pole isolating switch with at least 3mm contact separation in each pole and with a minimum rating of 13A All internal wiring is factory mounted and should not be altered or modified A...

Page 14: ...email service zipindustries co uk www zipwater co uk Electrical wiring diagram 1 2 4 5 3 N L 230V AC REF DESCRIPTION 1 Connection terminal 2 Thermal cut out 3 Electronic regulator 4 Electrical heating...

Page 15: ...Safety device e g temperature relief valve Tundish Metal Discharge Pipe D2 From Tundish with Continuous Fall Metal Discharge Pipe D1 From Temperature Relief Valve to Tundish with Continuous Fall Disch...

Page 16: ...hich you can reduce the use of electric energy Fig 8 Control panel Display of Set temperature Actual temperature of water in the heater Errors On Off button temperature setting Indication of the SMART...

Page 17: ...to start recording During the recording time the electronic regulator remembers your habits and takes them into account while heating the water after the recording period has ended The recording takes...

Page 18: ...ssary clean the limescale that accumulates depending on the quality quantity and temperature of the water inside the heater The service provider will also recommend the date for the next inspection de...

Page 19: ...nded to open the warm water tap on the mixing tap and let the water run for at least two minutes through the outlet pipe the water stream should be steady medium strength about as thick as a pencil Er...

Page 20: ...icates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling o...

Page 21: ...Provider or the cost of removal cartage and re installation of any component of the Aquapoint if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage result...

Page 22: ...22 Installation instructions user manual T210023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Notes...

Page 23: ...23 Installation instructions user manual T210023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Notes...

Page 24: ...T210023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk ZipWaterUK 14BertieWardWay Dereham Norfolk NR191TE 03456005005sales...

Reviews: