Installation instructions & user manual

 

T210023 v1.02 NOV 2018 - ZIP AP430S-AP4100S

Technical support 

 

Tel: 0345 6 005 005 email: service@zipindustries .co.uk  www.zipwater.co.uk

Installation

Connection to the electricity supply

•  Before connecting to the power supply network, 

install a power supply cord in the water heater, 

with a min. diameter of 1.5 mm

2

 (H05VV-F 3G 1.5 

mm

2

). 

•  To do this, the protective plate must be removed 

from the Aquapoint.

•  Switch off the mains electrical supply before 

removing the electrical cover panel or carrying 

out any work involving a live circuit or access to 

components that may be live.

•  Do not switch on the electrical supply until the 

Aquapoint is full of water.

•  This Aquapoint must be earthed.

•  The electrical connection to the heating elements must conform to current IEE wiring 

regulations and be permanently connected to the electrical supply through a double-pole 

isolating switch with at least 3mm contact separation in each pole and with a minimum 

rating of 13A.

• 

All internal wiring is factory mounted and should not be altered or modified.

•  A suitable supply cable should be fed through the grommet on the underside of the 

Aquapoint, connected to the live, neutral and earth connections on the terminal block and 

secured with the cable clamp provided.

•  Check all electrical connections for security and tightness.

• 

An over temperature cut-out is incorporated within the Aquapoint which is designed to 

operate at 79 - 84ºC. Should this happen, press the reset button.

IMPORTANT

• 

Before resetting the over temperature cut-out, isolate the electrical supply to the Aquapoint 

(prior to removing the electrical cover panel). 

• 

Ensure that the cover panel is replaced correctly and the retaining screws fitted before 

re-connecting the electrical supply.

Before service or maintenance work, disconnect the Aquapoint 

from the power supply network 

This must only be performed by a trained professional

!

!

Fig. 5 Removing the protective cover

!

!

Summary of Contents for Aquapoint AP430S SmartEco

Page 1: ...0023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Zip Aquapoint Installation instructions user manual Modelnumber AP430S...

Page 2: ...nstruction manual please visit www zipwater co uk to download the latest copy Please leave these instructions with the end user after installation General Product Description 3 Approvals 3 Technical D...

Page 3: ...ection for the vessel and the heating element Gradual erosion of the anode will occur depending on local conditions and in extreme cases conditions may cause rapid erosion resulting in particles being...

Page 4: ...564 49 740 Weekly electricity consumption without smart control kWh 16 215 28 501 30 049 57 832 Thermostat temperature setting eco Smart value 1 Storage volume V l 29 1 49 1 78 8 98 1 Mixed water at 4...

Page 5: ...ating suitable for the nomi nal current of the Aquapoint The cross sectional area of the connection cable must be appropriate for the power rating and location of the Aquapoint The connecting cable mu...

Page 6: ...unvented systems Temperatures in excess of approximately 43 C are perceived as hot especially by children and may cause a feeling of burning Please consider using the temperature controls This Aquapo...

Page 7: ...vertically on the wall can be drained through the heater s inlet pipe For this purpose it is advisable to install a T piece with an outlet valve between the inlet pipe and safety valve Please do not...

Page 8: ...ement 2000W 002 AQ0331 Gasket 005 94807 Bimetal safety cut out 006 AQ0320 Sacrifying anode 30 l 006 AQ0306 Sacrifying anode 50 l 006 AQ0307 Sacrifying anode 80 l 100 l 013 AQ0338 Fixing flange 019 950...

Page 9: ...rced where the Aquapoint will be installed The AP4 model may only be mounted vertically To facilitate future service interventions you are advised to install the heater in accordance with the installa...

Page 10: ...m Fig 4 pressurised mix taps should be used at the outlet points To ensure safe operation of the heater a safety valve should be installed on the inlet pipe to prevent elevation of pressure for more t...

Page 11: ...th the capacity of at least 5 of the heater volume To ensure proper operation of the safety valve periodical inspections must be carried out to remove limescale and make sure the safety valve is not b...

Page 12: ...xpansion vessel with wall bracket from cold inlet set take off 4 Hot water outlet 5 Temperature control 6 Neon indicator 7 Tundish to drain 8 Temperature and pressure relief valve 9 Expansion relief v...

Page 13: ...hrough a double pole isolating switch with at least 3mm contact separation in each pole and with a minimum rating of 13A All internal wiring is factory mounted and should not be altered or modified A...

Page 14: ...email service zipindustries co uk www zipwater co uk Electrical wiring diagram 1 2 4 5 3 N L 230V AC REF DESCRIPTION 1 Connection terminal 2 Thermal cut out 3 Electronic regulator 4 Electrical heating...

Page 15: ...Safety device e g temperature relief valve Tundish Metal Discharge Pipe D2 From Tundish with Continuous Fall Metal Discharge Pipe D1 From Temperature Relief Valve to Tundish with Continuous Fall Disch...

Page 16: ...hich you can reduce the use of electric energy Fig 8 Control panel Display of Set temperature Actual temperature of water in the heater Errors On Off button temperature setting Indication of the SMART...

Page 17: ...to start recording During the recording time the electronic regulator remembers your habits and takes them into account while heating the water after the recording period has ended The recording takes...

Page 18: ...ssary clean the limescale that accumulates depending on the quality quantity and temperature of the water inside the heater The service provider will also recommend the date for the next inspection de...

Page 19: ...nded to open the warm water tap on the mixing tap and let the water run for at least two minutes through the outlet pipe the water stream should be steady medium strength about as thick as a pencil Er...

Page 20: ...icates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling o...

Page 21: ...Provider or the cost of removal cartage and re installation of any component of the Aquapoint if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage result...

Page 22: ...22 Installation instructions user manual T210023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Notes...

Page 23: ...23 Installation instructions user manual T210023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Notes...

Page 24: ...T210023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk ZipWaterUK 14BertieWardWay Dereham Norfolk NR191TE 03456005005sales...

Reviews: