23
Installation instructions
805845UK v1.02 July 2018 - G4 Command Centre
Technical support
Tel: 0345 6 005 005 Email: [email protected] www.zipwater.co.uk
Note 1
This appliance is intended for use with the Zip HydroTap
G4 Command Centre
Note 2
Water connections must be pointing vertically upwards.
Note 3
The booster unit should be installed as close as possible to the Zip HydroTap
G4 as the 500mm
connection hoses cannot be lengthened.
Booster system
2.4 Braided hose connections
• The cold water inlet (blue cap) and hot water outlet (red cap) are marked on the rating plate. Connect
the braided hoses from the ‘BYPASS OUT’ fitting on the Command Centre to the water inlet of the
booster (blue cap) and from the outlet of the booster (red cap) to the ‘BYPASS IN’ fitting on the
Command Centre. Avoid exerting mechanical force on the booster. This can be achieved by using a
spanner on the flats of the inlet and outlet connections when tightening the braided hose connectors.
Do not over-tighten ! Tighten the braided hoses by hand, then turn a further 90
O
to
180
O
with a spanner.
• Once the water connections have been made, check for any leaks and rectify as necessary.
Strainer
Cold water connection
(inlet, 3/8” BSP)
Hold the hexagon while
tightening the braided
hose fittings
Braided hoses
Hot water connection
(outlet, 3/8” BSP)