16
Installation instructions
805845UK V1.02 July 2018 - G4 Command Centre
Technical support
Tel: 0345 6 005 005 Email: [email protected] www.zipwater.co.uk
1.3.1 Ventilation for all models
• The clearance envelope dimensions stated in the specification sheets and installation instructions must
be observed.
• Adequate ventilation must be provided to ensure that the cupboard space temperature does not exceed
35
0
C.
1.3.2 Preferred arrangement
• The vent kit supplied with the Command Centre should be used to provide adequate ventilation by
convection in normal usage.
Note
The vent kit has to be installed in a way that allows air to be drawn in from the bottom of the cupboard
and expelled through the top of the cupboard. The outlet vent
A
should be towards the top of the door (position
A2
) or side of the cupboard (position
A1
). (Where possible
air inlet vent and the air outlet vent should be positioned at
opposite ends of the same cupboard space).
A1
A2
Vent cut-out details
*
A
Air outlet vent
B
1.3.3 Alternative arrangement
In situations where the preferred arrangement does not
provide adequate ventilation by natural convection a Dual
exhaust fan kit* (SP93156) must be fitted to the cupboard
door or side (as shown in the illustration below) and
connected to the Command Centre
DIN socket.
* For dual
exhaust
fan cut-out
dimensions
see the
instructions
provided with
the kit.
B
A1
A2
B Air inlet vent
Note
Flat outlet vent detail shown above, louvred outlet vent
also supplied.
1.3 BC, BCS Commercial compact Command Centres
Ventilation
285
60
Ø
12 X 4
=
=
314
Ø
12 x 2
326
5
43max