Installation instructions
805845UK v1.02 July 2018 - G4 Command Centre
Technical support
Tel: 0345 6 005 005 Email: [email protected] www.zipwater.co.uk
1.5.3 Alternative arrangement (Dual fan kit)
In situations where the preferred arrangement cannot be used or will not work effectively e.g.
•
Single cupboard where the 100mm grille spacing cannot be achieved.
•
Where there are openings in the back of the cupboard allowing exhaust air to recirculate into the cupboard
space.
An SP93156 Dual exhaust fan kit* must be fitted in either arrangement A or B shown below and connected to
the DIN socket on the Command Centre
.
A
Fan kit fitted to kick board and with kick space duct fitted to the Command Centre.
B
Fan kit fitted to cupboard door (position
B1
) or side (position
B2
) and without kick space duct fitted
to the Command Centre.
*
For dual exhaust fan cut-out dimensions see the instructions provided with the kit.
B1
B2
A
B
1.5.4 Alternative arrangement (Vent tray)
In situations where cupboard width is 1000mm or greater, without central pillar and where vent grilles cannot
be fitted in the kick board (e.g. hospitals) use a
Vent tray kit
(CS SP93541).
Vent tray
100mm
min.
A vent grille, supplied should be used as an inlet vent and fitted to the cabinet side (adjacent to the
Command Centre air inlet) as shown below. It must take in air from the room or another ventilated space.
This space could be an adjacent cupboard, (via a communicating port) on condition that it does not contain
a heat generating appliance. The
vent grille or the angled inlet grille
supplied should be fitted in the
adjacent cupboard, observing
100mm separation from the vent
tray exhaust.
Ventilation