Page 14 MS - SOUND decoders MS440 to MS990 and MN - NON-SOUND decoders MN170 to MN340
MS590N18
Top side (with Next18), SOUND
NO connections on
bottom side
, therefore not shown here
MN180N18
Oberseite, mit Next18
. NICHT-SOUND
NO connections on
bottom side
, therefore not shown here
NOTE: External energy storage with
MS590N18
Due to the extreme miniaturization
, the “Next decoder” MS590N18 does NOT contain previsions
to connect an external energy storage directly.
It is possible to connect ELCOs (practically without limitation) to “GEM. Pluspol” (common posi-
tive) and ground, although, WITH additional components and a dielectric strength suitable for the
running voltage (usually 25 V):
The resistor prevents an inrush current too high, the diodes enable Service mode programming,
software updates and sound loading by dropping the voltage despite higher capacities.
External capacitors on miniature decoders over
-
Controller
STACO1/STACO3
STACO2
2 mini Goldcaps, STACO3 and Next-Decoder (example MS590N18) in series
The StayAlive controller is connected via wires to the solder pads
“
common positive
” and "
GROUND
" of the decoder (two-pole!).
STACO3A: 2 mini Goldcaps à
0.3 F
/2.7 V, 4 x 12 mm, 150,
000 µF;
STACO3B: 2 mini Goldcaps à
1 F
/2.7 V, 6.4 x 9.8 mm, 500,
000 µF
The STACO1 comes with 3 mini Goldcaps à 0.3 F/2.7 V, 4 x 12 mm as the
actual energy storage, which, connected in series, represent a capacity of
100,000
µF.
Of course, all 3 should preferably be connected, but it also works with 2 (with
about 50
% runtime) if there is a lack of space.
The wire connections between the
controller board and the mini Gold-
caps make their positional separation
possible, and thus in many cases the
accommodation of the StayAlive tech-
nology.
The STACO boards contain a step-up
voltage converter that sucks the Gold-
caps from their full charge state (8
V
for 3 pcs; 5.2
V for 2) to their almost
full discharge (2
V) and delivers a
constant 10 V voltage. This is enough
for driving and for uninterrupted sup-
ply of the sound amplifier (runs on
5
V) without volume loss.
StayAlive-Controller with
Next18-connection
A Next18 decoder can be
plugged on like on an adapter
board, the STACO2 then outputs
the decoder connections via 13
soldered strands.
The STACO2A set contains
13 soldered wires and
2x mini Goldcaps
à
0.3
F
/2.7
V, 4 x 12 mm
The STACO2
B
set contains
13 soldered wires and
2 mini Goldcaps à
1 F
/2.7 V,
6.4 x 9.8 mm
Summary of Contents for MS450
Page 5: ...MS SOUND decoders MS440 to MS990 and MN NON SOUND decoders MN170 to MN340 Page 5...
Page 61: ...MS SOUND decoders MS440 to MS990 and MN NON SOUND decoders MN170 to MN340 Page 61...
Page 85: ...MS SOUND decoders MS440 to MS990 and MN NON SOUND decoders MN170 to MN340 Page 85...
Page 87: ...MS SOUND decoders MS440 to MS990 and MN NON SOUND decoders MN170 to MN340 Page 87...
Page 88: ...Page88 MS SOUND decoders MS450 to MS990 ZIMO Elektronik GmbH Sch nbrunner Str 188 A 1120 Wien...