![ZIMO MS450 Instruction Manual Download Page 64](http://html1.mh-extra.com/html/zimo/ms450/ms450_instruction-manual_3828333064.webp)
Page 64 MS - SOUND decoders MS440 to MS990 and MN - NON-SOUND decoders MN170 to MN340
8
CV - Overview; CVs in numerical order
This overview summarizes all CVs in numerical order; mostly identically adopted from the descriptions in
the preceding (context-related) chapters of this manual, in some cases shortened. In this CV overview
there are
NO notes to SW versions (from SW version ...; see context-related chapters)
.
Red column on the left: Denotes the chapter in this manual the CV is described in its context - by click-
ing you can jump directly to the chapter
CV
Denomination
Range
Default Description
#1
Locomotive address
DCC:
1 - 127
MM:
1 - 255
3
The “short” vehicle address (DCC, MM)
In case of DCC operation:
Primary address as per CV #1 is only valid, if
CV #29 (basic configuration), Bit 5 = 0.
Otherwise, the address per CVs #17 & #18 is valid,
i.e. if CV #29, Bit 5 = 1.
#2
Start Voltage
Vstart
3-point speed table,
if CV #29, bit 4 = 0
1 - 255
1
Internal speed step (1 - 255)
applied as
lowest
external speed step (= speed step 1)
(applies to 14, 28, or 128 speed step modes)
= 1: lowest possible speed
#3
Acceleration time
0 - 255
(2)
The value multiplied by 0.9 equals acceleration time in
seconds from stop to full speed.
The effective default value for sound decoders is usually
not the value given here, but is determined by the loaded
sound project.
#4
Braking time
(Deceleration)
0 - 255
(1)
This CV, multiplied by 0.9, provides the time in sec for
the deceleration from full speed to stop.
The actual default value: see above!
#5
Top
Speed
Vhigh
3-point speed table,
if CV #29, bit 4 = 0
0 - 255
0, 1
equals 255
Internal speed step (1 - 255)
applied as
highest
external speed step (i.e. for the exter-
nal speed step 14, 28 or 128, depending on the speed
step mode according to CV #29, bit 1 = 0:
=0: equals 255 as highest speed step
=1: equals 255 as highest speed step
#6
Medium
Speed
Vmid
1,
¼ to ½
of the
Value in
CV #5
1
(= @ 1/3 of top
speed)
Internal speed step (1 - 255)
for
medium
externa speed step (i.e. for the external
speed step 7, 14 or 64, depending on the speed step
mode 14, 28 or 128 according to CV #29, bit 1)
”1" = default (Medium speed is set to one third of the top
speed. I.e. if CV #5 = 255 the curve is the same as if CV
#6 would be programmed to 85).
The speed curve resulting from CVs #2, #5 and #6
is automatically smoothed out, therefore no sharp bends.
#7
SW version number
Also see CV #65
Sub-Version number
Read only
-
This CV holds the firmware version number currently in
the decoder.
CV #7 = number of the
“main” version
CV #65 = Sub-version number
CV
Denomination
Range
Default Description
#8
Manufacturer
ID
and
HARD RESET
by CV
#8 = „8“
or CV #8 = 0
Read only
always shows
“145” for
ZIMO
ID
Pseudo-
programming
see descr.
on the right
145
(= ZIMO)
Reading out this CV always result in “145” (”10010001”),
the number issued for ZIMO by the NMRA.
Additionally, this CV is used to start various resetting pro-
cedures by Pseudo programming.
“Pseudo programming” means that the entered value is not really
stored, but rather used to start a defined action.
CV #8 = “3”
→
21MTC decoder FO3, FO4 logic-level
CV #8 = “4”
→
21MTC decoder FO3, FO4 normal
CV #8 = “5”
→
21MTC decoder FO5, FO6 logic-level
CV #8 = “6”
→
21MTC decoder FO5, FO6 normal
CV #8 = “8”
→
HARD RESET (NMRA standard);
all CVs return to the last active
CV set or
sound project,
or (if no such set was active before)
to the default values listed in this CV table.
CV #8 = “0”
→
NOT recommended (service use only),
default values of the table
#9
Motor control-
period
or frequency
and
EMF-sampling
Rate
(sampling rate,
Sampling time)
Total PWM period
55
High fre-
quency,
medium
sampling
rate.
01 - 99
High fre-
quency
with modi-
fied sam-
pling rate
55
High fre-
quency,
medium
Sampling
rate
= 55: Default motor control with high frequency (20 kHz),
medium EMF sampling rate that adjusts between 200Hz
(low speed) and 50Hz and medium EMF sampling time.
= 0: equal to 0 (is converted automatically)
<> 55 and <> 0: Modification of the default setting,
each divided in: tens digit for sampling rate
and ones digit (sampling time).
Tens digit 1 - 4: Sampling rate lower than
default (less noise)
Tens digit 6 - 9: Sampling rate higher than default
(to combat juddering!)
Ones digit 1 - 4: EMF-sampling time shorter than
by defaiult (works well for Faulhaber, Maxxon, ...
less noise, more power)
Ones digit 5 - 9: EMF-sampling time longer than default
(may be needed for round motors or similar)
#10
Motorola
Subsequent ad-
dresses
0-3
0
Decimal:
0= No Subsequent address
1= One Subsequent address for F5-F8
2= Two Subsequent addresses for F5-F12
3= Three Subsequent addresses for F5-F16
#12
Possible operating
modes
-
117
Bit 0 - DC analog
0 = disabled 1 = enabled
Bit 2
– DCC NOT deactivatable 1 = enabled
Bit 4 - AC analog
0 = disabled 1 = enabled
Bit 5 - MM 0 = disabled
1 = enabled
Bit 6 - mfx
0 = disabled 1 = enabled
Value 0 = all modes enabled
Summary of Contents for MS450
Page 5: ...MS SOUND decoders MS440 to MS990 and MN NON SOUND decoders MN170 to MN340 Page 5...
Page 61: ...MS SOUND decoders MS440 to MS990 and MN NON SOUND decoders MN170 to MN340 Page 61...