Explorer, browse to your CD-ROM drive, and double-click the launch.exe file to 

launch the installer.

b. DemoShield provides several installation options. Select Install Zilog Developer 

Studio to install now. You can install other software and accompanying 

documentation later.

c. Follow the on-screen instructions to complete the installation.

Step 3. Install the USB Smart Cable Driver Software and 
USB Smart Cable

The USB Smart Cable connects the development kit to a high-speed or full-speed USB 
port on your ZDS II host system. Its internal opto-isolator electrically isolates the develop-
ment kit circuitry from the USB Smart Cable. 

The USB Smart Cable is enclosed in a black box that connects to the host PC via a USB 
cable (included in kit). The USB Smart Cable housing is connected to the development kit 
via a six-circuit ribbon cable.

Install the USB Smart Cable for your operating system, as described below. Do not con-
nect power to either the MC MDS board or application board before connecting a USB 
Smart Cable to the host PC and development board.

32- and 64-Bit Windows 7

Observe the following steps to install the USB Smart Cable and associated driver software 
for Windows 7 systems.

a. Connect the USB Smart Cable to the host PC. The 

Found New Hardware

 dialog 

box is displayed.

b. Select 

Locate and install driver software (recommended)

. The 

User Account 

Control

 window is displayed; click 

Continue

. The 

Driver Software Installation

 

window is displayed, followed by the 

Found New Hardware–USB Smart Cable

 

dialog box.

c. Select 

I don't have the disc. Show me other options

.

d. Select 

Browse my computer for driver software (advanced)

.

e. Browse to one of the following driver directories based on the Win 7 OS you use.

For 32-bit Windows 7 systems:

<ZDS II Installation Directory>\device drivers\USB\x32

<ZDS II Installation CD>\device drivers\USB\x32

Summary of Contents for Z8FMC16100 Series

Page 1: ...pply requirements to power the 3 phase motor supplied with the kit How to run the kit s preloaded sample code in standalone mode How to connect the kit to your development PC Running the sample code i...

Page 2: ...hip s internal Flash memory This section describes a series of steps for setting up the kit and running the sample code in standalone mode Table 1 ZDSII System Requirements Recommended Configuration M...

Page 3: ...t the motor leads to the spade lugs on the 3 Phase Motor Control Application Board as shown in Figure 2 Figure 1 MC MDS Board Mounted on 3 Phase Motor Control Application Board Step 2 Set Switches and...

Page 4: ...406 0111 Page 4 of 15 Speed Potentiometer R7 to its mid point Refer to the Z8FMC16100 Series Motor Control Motor Control Development Kit User Manual UM0192 for detailed jumper descriptions Figure 2 Z8...

Page 5: ...parately between the AC cord recepta cle on the end of the power supply and an electrical outlet Step 4 Connect the 5V DC Universal Power Supply to the MC MDS Board Connect the 5V DC power supply to t...

Page 6: ...ug the 5V DC universal power supply from the MC MDS board Executing Sample Code in Debug Mode using ZDSII Observe the following steps to execute the sample code in debug mode using ZDSII 1 Stop the pr...

Page 7: ...onnected to the development kit via a six circuit ribbon cable Install the USB Smart Cable for your operating system as described below Do not con nect power to either the MC MDS board or application...

Page 8: ...d followed by the Found New Hardware USB Smart Cable dialog box c Select I don t have the disc Show me other options d Select Browse my computer for driver software advanced e Browse to one of the fol...

Page 9: ...e Wizard should activate automatically after connecting the Zilog USB device for the first time b Click Next in the Found New Hardware Wizard after it has been activated c Select Search for a suitable...

Page 10: ...ers on the MC MDS board are set as described in Step 2 Set Switches and Jumpers on page 3 b Connect and apply power to the development kit as described in Running in Standalone Mode on pages 2 through...

Page 11: ...mples Z8FMC16 Z8FMC16_MotorDemo src f Select the motordemo zdsproj file and click Open The initial ZDSII program screen opens see Figure 4 To view the project source files double click the Project Fil...

Page 12: ...ck OK i Click the Rebuild All icon to build the project Wait for the build to complete as indicated by the Build Complete confirmation in the Status window at the bottom of the screen j Click the Rese...

Page 13: ...se motor should start running If the motor does not run start over from Step c on page 10 m Use the Direction Switch S1 to change the direction in which the motor spins Use Speed Potentiometer R7 to a...

Page 14: ...S board After you have connected the 5V DC power supply to the MC MDS board the green 3 3V DC LED D4 must be illuminated If it is not illuminated verify that power is properly connected to the board a...

Page 15: ...an be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness Document Disclaimer 2011 Zilog Inc All rights reserved Information in this...

Reviews: