12. Watchdog Timer
102
Watchdog Timer Counter Registers
The Watchdog Timer Counter registers hold the current value of the down counter.
Application software reads these registers to determine the current count value. A
reload operation automatically transfers the contents of the Watchdog Reload registers
to the Watchdog Timer registers.
Register:
Access:
Address:
7
6
5
4
3
2
1
0
15
14
13
12
11
10
9
8
WDT Count High
F4C4h
Read
WC31
WC30 WC29 WC28 WC27 WC26 WC25 WC24
WC31
WC23 WC22 WC21 WC20 WC19 WC18 WC17 WC16
Current WDT Count High
Register:
Access:
Address:
7
6
5
4
3
2
1
0
15
14
13
12
11
10
9
8
WC31
WDT Count Low
F4C6h
Read
Current WDT Count Low
WC15 WC14 WC13 WC12 WC11 WC10 WC9 WC8
WC7 WC6
WC5 WC4
WC3 WC2
WC1 WC0
Watchdog Timer Counter Registers