Part IV Setting Parameters
BECS-129S Singular-head Computerized Embroidery Machine
44
there will be no returning. If the value is larger than 0, there will be auto
return and the returned stitches is the set value.
Treat After Patch: (Options: Normal, Reduce, Stop)
This is to set the machine speed after patching. If it is “Normal”, the
machine will keep the normal embroidery speed. If it is “Reduce”, the
machine will run in lower speed for several stitches and then return to the
normal speed. If it is “Stop”, the machine will stop automatically and the
machine will not continue normal embroidery until it is stared again.
Start Sti. no T. B. D.: (Options: 0~15)
This parameter is to decide not to check thread break in how many
stitches when the machine start running.
T. B. Detect at Jump: (Options: Yes, No)
This is to decide whether to check thread break during jump stitch in
embroidery. If it is “No”, the machine will not check thread break when
encountering jump stitch in embroidery. If it is “Yes”, the machine will not
check thread break only in the circumstance that the system encounters the
continuous jump stitch without the falling of needle bar.
Long Sti. Divide: (Options: No, 7~12)
This parameter is to decide whether to divide the long stitches in
embroidery and to determine the value of stitch length in dividing.
If the stitch is too long, the main shaft will reduce its rotation speed. The
longer the stitch is, the lower the speed will be. The machine can divide the
Summary of Contents for BECS-129S