![Zeversolar Zeverlution 1000S Assembly, Installation And Operating Instructions Download Page 46](http://html2.mh-extra.com/html/zeversolar/zeverlution-1000s/zeverlution-1000s_assembly-installation-and-operating-instructions_3582575046.webp)
Installation and Operating Instructions V03
45
7.1.1 Display
The display messages consist of 16 characters×2 lines. The bottom line always
shows the current output (Pac = xxxx.xW). The top line shows the current state by
default, it will switch to different state information by pressing the control button,
as follows. At the last item, the first line display ComBox IP addr(it will show 0.0.0.0
without Combox ), and bottom display state that connect ZeverCloud or not.
Line 1
State information
E-today
Daily energy
E-total
Energy generated since the inverter has been
installed
Vpv
DC input voltage
Ipv
DC input current
Vac
Grid volt
Iac
Present output current
Frequency
Grid frequency
Model
Type name
Set Language
Selected language
Version
Firmware version
Serial No.
Serial number
IP Addr
ComBox IP addr
Line 2
Pac = xxxx.xW
Current output power
connect state
Connect solarcould or not