Section 5. Installation
5-11
Connection to a GE EXEC II Base
For:
Zetron Model 37-MAX
To:
GE EXEC II Base
Using:
709-7179 Generic Radio Cable
37-MAX End
Function
J1
pin#
Wire
Color
Radio End
Connection/Notes
+12 volts DC
1
RED
H20 (A+)
Ground
2
BLACK
Chassis ground
Discriminator Input
3
WHITE
J907, pin 8 (Vol Hi)
Ground
4
BRAID
No connection
TX Audio Output
5
BLUE
H36 (Tone Hi)
Ground (spare)
6
N/C
PTT Output
7
ORANGE
J907, pin 10 (PTT)
Ground
8
BROWN
Ground trace
COR Input
9
YELLOW
J913, pin 4 (CAS)
CTCSS/DCS Encode
10
GREEN
J907, pin 6 (CG Hi)
GE EXEC II Configuration
To modify the radio for full-duplex (repeater) operation, follow these steps:
1. Remove Q905 and Q908 on the System Audio Squelch board (SAS board).
2. Install a wire jumper from the Q908 emitter solder pad to the Q908 collector solder pad.
3. Care should be taken not to damage the transmitter PA due to continuous duty operation.
Summary of Contents for 37-MAX
Page 72: ...Section 6 Repair 6 6 MODEL 37 MAX REPEATER PAL 702 9808A Schematic 1 3...
Page 73: ...Section 6 Repair 6 7 2 3...
Page 74: ...Section 6 Repair 6 8 3 3...
Page 75: ...Section 6 Repair 6 9 MODEL 37 MAX REPEATER PAL 702 9808A Silkscreen...
Page 76: ...APPENDIX A PROGRAMMING LOG A 1 OVERVIEW A 1 SYSTEM PROGRAMMING A 2 USER PROGRAMMING A 3...