If you do not succeed in starting the engine
Ignition system failure signalization
*Coolant heater
Return the key to '0' position. Wait 60 second and repeat
the start.
Never help the stopping engine by a starter.
You are being exposed to the danger of starter
damage.
PCLPN038
A failure of the glowing system is indicated by flashing of
the glowing signal lamp (3) and simultaneous activation of
the red (1) or orange (2) signal lamp. The failure code is
displayed in the screen.
- If the engine is at standstill, the glowing signal lamp
flashes once a second and the signal lamp (2) glows,
glowing in the emergency mode is performed similarly as
at low temperatures regardless the temperature of the
cooling liquid.
- If the engine is at standstill, the glowing signal lamp
flashes twice a second and the signal lamp (2) glows, the
glowing is turned off (not functioning).
- If the engine is running, the glowing signal lamp glows
permanently and the signal lamp (1) glows, there is
a failure of the glowing control and glowing was not
finished. The failure must be immediately eliminated since
there is a danger that the accumulator will be discharged.
P18N056
Is mounted on the right side of engine block.
output 1,000 W
voltage 230 V
PGPPN136
OPERATION
72
Summary of Contents for Proxima CL 80
Page 1: ...OPERATOR S MANUAL PROXIMA CL 03 2018 Tractor is Zetor Since 1946 80 90 100 110...
Page 3: ...2...
Page 11: ...10...
Page 33: ...NOTES 32...
Page 91: ...NOTES 90...
Page 111: ...NOTES 110...
Page 131: ...NOTES 130...
Page 147: ...Fuse panel B P18N083 ELECTRICAL INSTALLATION 146...
Page 163: ...NOTES 162...
Page 181: ...NOTES 180...
Page 187: ...NOTES 186...
Page 203: ...NOTES 202...
Page 208: ...207...