PG8
ZCOMV24 |CONTROL PANEL | COMANDO 24V
LED
COLOR
FUNCTION DESCRIPTION
L01
RED
Comes on when the PEDESTRIAN start command is activated and goes off when released.
L02
RED
Comes on when the START command is activated and goes off when released.
L03
RED
Always on. Goes off when the photocell is intercepted interrupting the PHOTO beam.
L04
RED
Comes on when SAFETY EDGE is activated and while programming.
L05
RED
Comes on when the STOP command is activated and goes off when released.
L06
RED
Always on. Goes off when the CLOSING LIMIT SWITCH of motor is reached.
L07
RED
Always on. Goes off when the OPENING LIMIT SWITCH of motor is reached
CODE
RED
Blinking when wrongly configured.
DIP 1
ON
WORKING LOGIC: STEP BY STEP WITH AUTOMATIC CLOSURE
(for other configuration see the DIP SWICH paragraph)
OFF
DIP 2
ON
OFF
DIP 3
ON
GATE PAUSE BEFORE CLOSING 60 SECOND
OFF
GATE PAUSE BEFORE CLOSING 15 SECOND
DIP 4
ON
SOFT STOP ENABLED
OFF
SOFT STOP DISABLED
DIP 5
ON
BLINK 2 SECONDOS BEFORE OPENING ENABLED
OFF
BLINK 2 SECONDOS BEFORE OPENING DISABLED
DIP 6
ON
ANTI-CRUSHING FUNCTION DIFFERENT SENSIVITY WHILE OPENING AND CLOSING (GARAGE DOORS)
OFF
SAME SENSIVITY FOR ANTI CRUSHING FUNCTION (SLIDING GATES)
DIP 7
ON
AUTOMATIC CLOSING AFTER PHOTOCELLS ARE INTERRUPTED ENABLED
OFF
AUTOMATIC CLOSING AFTER PHOTOCELLS ARE INTERRUPTED DISABLED
DIP 8
ON
PHOTOCELLS READING ENABLED
OFF
PHOTOCELLS READING DISABLED
DIP 9
ON
STOP BUTTON READING ENABLED
OFF
STOP BUTTON READING DISABLED
DIP 10
ON
SAFETY EDGES READING ENABLED
OFF
SAFETY EDGES READING DISABLED
LED DESCRIPTIONS
DIP SWITCH DEFAULT (FACTORY) SETTINGS
The default settings are highlighted in the boxes with grey background.
Summary of Contents for COMANDO 24
Page 2: ...PG2 ZCOMV24 CONTROL PANEL COMANDO 24V ...
Page 7: ...PG7 ZCOMV2 CONTROL PANEL COMANDO 24V CONNECTIONS ...
Page 9: ...PG9 ZCOMV2 CONTROL PANEL COMANDO 24V FOTO FOTO 180 PHOTOCELLS CONNECTIONS ...
Page 10: ...PG10 ZCOMV24 CONTROL PANEL COMANDO 24V FOTO IN FOTO BATTERY ...