PG4
ZCOMV24 |CONTROL PANEL | COMANDO 24V
PROGRAMMING PRE-RECOMENDATIONS
Before proceeding to the control board configuration, note the
following points listed in the table below in order to better un
-
derstand the control board function:
M2 Connector
Limit-switches :
14 and 12 • Make sure that the limit switche connections are
synchronized with the L6 and L7 LEDs (). Test it by moving the
automation limit-switch spring by hand to check that the L6
and L7 LEDs in the correct way (L7 LED turns off with a closing
signal and the L6 LED turns off with the opening signal).
Safety circuits:
11 • This circuit allows the connection of all types of safety de
-
vices such as photocells, safety edges etc. This device operates
only in the gate closing and it reverses the automations move
-
ment, when activated.
14 • This circuit allows the connection of all types of safety de
-
vices such as photocells, safety bands, etc. This device acts in
both opening and closing directions and reverses the automa
-
tions movement for 2 seconds, when activated.
M1 Connector
05 • This is an intermittent output and must be used with lamps
that do not have electrical circuit because the output itself is
programmed to create a flashing effect on the bulb (apply only
a lightbulb with socket and bulb 24 Vdc 10W max). It does quick
flashes when it is opening, it remains off when paused and it
flashes slowly during closure.
3. CONFIGURATION
INSTALATION PROCESS
TRANSMITTER PROGRAMMING
01 • Place all the dippers in ON position (UP). In case of not
using safety device at 11-12-13/M2 terminal (ex: photocells),
place the dipper 8/9/10 in ON to disable it.
02 • Unlock the motor, place the gate in the middle position
and re-lock the engine.
03 • Connect the power to the control board check if the li
-
mit-switches are activated correctly. When wiring the limit-swi
-
tches at terminals 01 and 02, the L6 and L7 LEDs will remain
lit. When moving the spring manually towards closing position,
the L7 LED must turn off and when moving it towards opening
position, the L6 LED must go off too. If the LEDs are turning off
opposite to the correct way, if L7 for opening and L6 for closing,
swap the wires from 14 and 15 terminals. Close the gate and
re-lock the motor.
04 • When the gate arrives at the closed position, press the
SW1 PROGRAM button located on the control board for 2 se
-
conds until the CODE LED (see connection diagram page) stays
illuminated. immediately press the transmitter button you want
to be the total opening key.
NOTE: When the transmitter button is pressed, the CODE LED
must blink, indicating it is receiving the code.
05 • Release the first button and then press the SW1 PRO
-
GRAMM button twice to memorize the pedestrian opening
button. The CODE LED will blink twice, indicating it is receiving
the code. Right away, press the second transmitter button you
want to be the pedestrian opening key, release it and wait for
the CODE LED turns off.
NOTE: If you select a button other than the nº 2 for pedestrian
opening, the control board will recognize it as a complete ope
-
ning button, which means it will override the first pressed but
-
ton. If the pedestrian opening is not required then do not press
the nº2 button and wait for the CODE LED to turn off.
ONCE CONFIGURED, THE PEDESTRIAN OPENING FUNCTION
WILL MOVE THE GATE JUST FOR 8 SECONDS FROM THE CLO-
SED POSITION AND WILL PERMIT A PARTIAL GATE OPENING.
06 • The transmitter is now configured.
NOTE: After setting up a transmitter type, the control board will
only accept transmitters from the same type, it means, if the
first transmitter is Rolling Code, they must all be Rolling Code
for the central to accept them. To program other transmitters,
repeat the steps from nº04.
ERASE ALL THE TRANSMITTERS FROM THE CONTROL BOARD
01 • With the gate closed, hold the SW1 button continuously.
The CODE LED lights up and wait for 15 seconds until it turns off.
Release the PROGRAM BUTTON
SW1 and the LED will flash three times to signal the MEMORY
RESET has succeeded.
PROGRAMMING THE WORKING FUNCTIONS
01 • With the gate closed set the Dip-Switches to obtain the
required operating functions:
DIP SWITCH FUNCTIONS
DIP 1 - ON and DIP 2 - ON
Step-by-step function with self-closing.
• During the opening it accepts transmitter signals.
• When the gate stops it remains so for the programmed
pause time and then automatically closes. (FACTORY SET 60
seconds)
• If it receives a transmitter signal during closing, it reverses.
• In pause time, it anticipates the closing