PG4

ZCOMV24 |CONTROL PANEL | COMANDO 24V

PROGRAMMING PRE-RECOMENDATIONS

Before proceeding to the control board configuration, note the 

following points listed in the table below in order to better un

-

derstand the control board function:

M2 Connector

Limit-switches :

14 and 12 • Make sure that the limit switche connections are 

synchronized with the L6 and L7 LEDs (). Test it by moving the 

automation limit-switch spring by hand to check that  the  L6 

and L7 LEDs in the correct way (L7 LED turns off with a closing 

signal and the L6 LED turns off with the opening signal).

Safety circuits:

11 • This circuit allows the connection of all types of safety de

-

vices such as photocells, safety edges etc. This device operates 

only in the gate closing and it reverses the automations move

-

ment, when activated.

14 • This circuit allows the connection of all types of safety de

-

vices such as photocells, safety bands, etc. This device acts in 

both opening and closing directions and reverses the automa

-

tions movement for 2 seconds, when activated.

M1 Connector

05 • This is an intermittent output and must be used with lamps 

that do not have electrical circuit because the output itself is 

programmed to create a flashing effect on the bulb (apply only 

a lightbulb with socket and bulb 24 Vdc 10W max). It does quick 

flashes when it is opening, it remains off when paused and it 

flashes slowly during closure. 

3. CONFIGURATION

INSTALATION PROCESS

TRANSMITTER PROGRAMMING

01 • Place all the dippers in ON position (UP). In case of not 

using safety device at 11-12-13/M2 terminal (ex: photocells), 

place the dipper 8/9/10 in ON to disable it.

02 • Unlock the motor, place the gate in the middle position 

and re-lock the engine.

03 • Connect the power to the control board check if the li

-

mit-switches are activated correctly. When wiring the limit-swi

-

tches at terminals 01 and 02, the L6 and L7 LEDs will remain 

lit. When moving the spring manually towards closing position, 

the L7 LED must turn off and when moving it towards opening 

position, the L6 LED must go off too. If the LEDs are turning off 

opposite to the correct way, if L7 for opening and L6 for closing, 

swap the wires from 14 and 15 terminals. Close the gate and 

re-lock the motor.

04 • When the gate arrives at the closed position, press the 

SW1 PROGRAM button located on the control board for 2 se

-

conds until the CODE LED (see connection diagram page) stays 

illuminated. immediately press the transmitter button you want 

to be the total opening key.

NOTE: When the transmitter button is pressed, the CODE LED 

must blink, indicating it is receiving the code. 

05  •  Release  the  first  button  and  then  press  the  SW1  PRO

-

GRAMM  button  twice  to  memorize  the  pedestrian  opening 

button. The CODE LED will blink twice, indicating it is receiving 

the code. Right away, press the second transmitter button you 

want to be the pedestrian opening key, release it and wait for 

the CODE LED turns off. 

NOTE: If you select a button other than the nº 2 for pedestrian 

opening, the control board will recognize it as a complete ope

-

ning button, which means it will override the first pressed but

-

ton. If the pedestrian opening is not required then  do not press 

the nº2 button and wait for the CODE LED to turn off.

ONCE CONFIGURED, THE PEDESTRIAN OPENING FUNCTION 

WILL MOVE THE GATE JUST FOR 8 SECONDS FROM THE CLO-

SED POSITION AND WILL PERMIT A PARTIAL GATE OPENING.

06 • The transmitter is now configured.

NOTE: After setting up a transmitter type, the control board will 

only accept transmitters from the same type, it means, if the 

first transmitter is Rolling Code, they must all be Rolling Code 

for the central to accept them. To program other transmitters, 

repeat the steps from nº04.

ERASE ALL THE TRANSMITTERS FROM THE CONTROL BOARD

01 • With the gate closed, hold the SW1 button continuously. 

The CODE LED lights up and wait for 15 seconds until it turns off. 

Release the PROGRAM BUTTON

SW1 and the LED will flash three times to signal the MEMORY 

RESET has succeeded.

PROGRAMMING THE WORKING FUNCTIONS

01 • With the gate closed set the Dip-Switches to obtain the 

required operating functions:

DIP SWITCH FUNCTIONS

DIP 1 - ON and DIP 2  - ON

Step-by-step function with self-closing.

• During the opening it accepts transmitter signals.

• When the gate stops  it remains so for the programmed 

pause time and then automatically closes. (FACTORY SET 60 

seconds)

• If it receives a transmitter signal during closing, it reverses.

• In pause time, it anticipates the closing

Summary of Contents for COMANDO 24

Page 1: ...PG1 ZCOMV2 CONTROL PANEL COMANDO 24V USER MANUAL AND CONFIGURATION ZCOM24 VER1 0 01012018_REV1 IT EN FR COMANDO 24 CONTROL UNIT SLIDING GATES AND GARAGE DOORS 24V made in italy ...

Page 2: ...PG2 ZCOMV24 CONTROL PANEL COMANDO 24V ...

Page 3: ...mains power supply The installer must inform the client how to handle the product in case of emergency and provide this manual to the user Keep remote controls away from children to prevent the au tomated system from being activated involuntarily The customer shall not under any circumstances attempt to repair or tune the automation and must call a qualified techni cian only Connect the automation...

Page 4: ...losing swap the wires from 14 and 15 terminals Close the gate and re lock the motor 04 When the gate arrives at the closed position press the SW1 PROGRAM button located on the control board for 2 se conds until the CODE LED see connection diagram page stays illuminated immediately press the transmitter button you want to be the total opening key NOTE When the transmitter button is pressed the CODE...

Page 5: ...ds before start opening com mences DIP 6 ON Enables more force torque during the opening operation The motor force will be double and sensitivity less during opening of that set by TR11 and during closing will be as per the setting of TR11 NOTE USED ONLY FOR OVERHEAD GARAGE DOORS APPLI CATION DIP 6 OFF Enables anti crushing function during opening and closing has the same obstacole sensitive funct...

Page 6: ...cept wire safety edges USE DIP 10 to set function ON BOARD MAGNETIC LIMIT SWITCH FUNCTION the control unit is equipped with a CN2 connector to accommodate a ma gnetic limit switch module directly welded on control panel on demand and just for Z01 model BATTERY EMERGENCY FUNCTION BLACK START The control board is equipped to operate in emergency with a single 12v battery and with a battery rechargin...

Page 7: ...PG7 ZCOMV2 CONTROL PANEL COMANDO 24V CONNECTIONS ...

Page 8: ... CLOSURE for other configuration see the DIP SWICH paragraph OFF DIP 2 ON OFF DIP 3 ON GATE PAUSE BEFORE CLOSING 60 SECOND OFF GATE PAUSE BEFORE CLOSING 15 SECOND DIP 4 ON SOFT STOP ENABLED OFF SOFT STOP DISABLED DIP 5 ON BLINK 2 SECONDOS BEFORE OPENING ENABLED OFF BLINK 2 SECONDOS BEFORE OPENING DISABLED DIP 6 ON ANTI CRUSHING FUNCTION DIFFERENT SENSIVITY WHILE OPENING AND CLOSING GARAGE DOORS OF...

Page 9: ...PG9 ZCOMV2 CONTROL PANEL COMANDO 24V FOTO FOTO 180 PHOTOCELLS CONNECTIONS ...

Page 10: ...PG10 ZCOMV24 CONTROL PANEL COMANDO 24V FOTO IN FOTO BATTERY ...

Page 11: ...EN CLOSE POSITION CONNECTION NOTE ON BOARD MAGNETIC LIMIT SWITCH FUNCTION the control unit is equipped with a CN2 connector to accommodate a magnetic limit switch module directly welded on control panel on demand and just for Z01 model will be also provided two magnetic stoppers for end limit switch positions ...

Page 12: ...d posi tion Lock motor again and turn off power supply for 5 seconds Reconnect it and send start si gnal using transmitter Gate opened but didn t close again Check if there is any obstacle in front of the photocells Check if any of the control devices key selector push button video intercom etc of the gate are jammed and sending permanent signal to control unit Consult a qualified ZERO tech nician ...

Page 13: ...ere is some security system malfunction photocells safety edges etc 1 Close with a link wire all safety systems on the control board check manual of the control board in question If the automated system starts working normally check for the problematic device 2 Remove one link wire at a time until you find the malfunction device 3 Replace it for a functional device and check if the motor works cor...

Page 14: ...CE Directive and that all the rules and or technical specifications shown below have been applied EN 60335 1 EN 60204 1 EN 55014 EN 6100 3 2 EN 6100 3 3 EN 6100 4 2 EN 6100 4 4 ENV50140 EN50081 1 EN50082 1 ALTAVILLA VICENTINA VI Italia 01 07 2016 and he also declares that it is not allowed to commission the device until the machinery where it will be incorporated or who se it will become a compone...

Page 15: ...PG15 ZCOMV2 CONTROL PANEL COMANDO 24V ...

Page 16: ...PG16 ZCOMV24 CONTROL PANEL COMANDO 24V ZERO SRLS Via Olona 110 Gallarate VA ITALIA info miozero it www miozero it ...

Reviews: