background image

PG3

ZCOMV2 |CONTROL PANEL | COMANDO 24V

CONTENTS

 1. 

SAFETY INSTRUCTIONS

 

STANDARDS TO FOLLOW 

2. 

THE CONTROL BOARD

 

TECHNICAL SPECIFICATIONS

 

PROGRAMMING PRE-RECOMENDATIONS

3 CONFIGURATION

 

DIP-SWITCHES FUNCTION’S BOARD

4. TROUBLESHOOTING

5. 

FINAL CONSUMERS INSTRUCTIONS

 

INSTRUCTIONS FOR SPECIALIZED INSTALLERS

6. 

WIRING DIAGRAM

7. 

CONTROL BOARD COMPONENT CONNECTION

1. SAFETY INSTRUCTIONS

STANDARDS TO FOLLOW 

ATTENTION:

•To ensure the safety of people, it is important that you read 

all of the following instructions. Incorrect installation or incor

-

rect use of the product may cause physical injury and material 

damage.

•Keep these instructions in a safe place for future reference.

•This product was designed and produced strictly for the use 

indicated in this manual. Any other use, not expressly indicated 

here in, could compromise the good condition/operation of the 

product and/or be a source of danger.

•ZERO SRL is not responsible for the improper use of the pro

-

duct, or other use than that for which it was designed.

•ZERO SRL is not responsible if safety standards are not taken 

into account when installing the equipment, or for any defor-

mation that may occur to it.

•ZERO SRL is not responsible for the safety and proper opera

-

tion when using components not sold by them.

•Do  not  make  any  modification  to  the  operator  components 

and / or their  accessories.

•Before  installation  unplug  the  automation  from  the  mains 

power supply.

•The installer must inform the client how to handle the product 

in case of emergency and provide this manual to the user.

•Keep remote controls away from children, to prevent the au-

tomated system from being activated involuntarily.

•The customer shall not, under any circumstances attempt to 

repair or tune the automation and must call a qualified techni

-

cian only.

•Connect the automation to a 230V plug with ground wire.

•Control board for indoor use.

2. 

THE CONTROL BOARD

TECHNICAL SPECIFICATIONS

          

Power supply:

12/24 VAC 80W

Lightbulb’s output:

24 VDC 10W max

Motor’s output:

1x24V 60W max

Aux. accessories output: 

12 VDC 8W, max

Working temperature:

-20°C a +50°C

Radio Receptor:

Incorporated 433,92 Mhz

OP Transmitters:

Rolling Code

Max. memory capacity: 

200 codes max

CONNECTOR’S DESCRIPTION

M1 Connector

01 • 12V battery input 

02 • 0V battery input 

03 • Motor’s input  (+) positive

04 • Motor’s input  (-) negative 

05 • Light bulb connection output (-) negative 

06 • Light bulb connection output  (+) positive

07 • Power supply output for accessories 12V AC - 8W máx. 

08 • Power supply output for accessories 0V

M2 Connector

09 • Pedestrian START input (NA)

10 • Open/close input (NA)

11 • Safety device input  PHOTOCELLS- complete direction 

         inversion (NC)

12 • STOP button’s input (NC) 

13 • Safety device input EDGE- 2 seconds inversion (NC wire )

14 • Opening limit-switch input signal (NC)

15 • Closing limit-switch input signal (NC)

16 • Safety device and start input common

M3 Connector

17 • Antenna cable screen input

18 • Antenna input

D Connector

19 • 0V VCA transformer supply input 

20 • 12V VCA transformer supply input 

21 • 20V VCA transformer supply input 

Summary of Contents for COMANDO 24

Page 1: ...PG1 ZCOMV2 CONTROL PANEL COMANDO 24V USER MANUAL AND CONFIGURATION ZCOM24 VER1 0 01012018_REV1 IT EN FR COMANDO 24 CONTROL UNIT SLIDING GATES AND GARAGE DOORS 24V made in italy ...

Page 2: ...PG2 ZCOMV24 CONTROL PANEL COMANDO 24V ...

Page 3: ...mains power supply The installer must inform the client how to handle the product in case of emergency and provide this manual to the user Keep remote controls away from children to prevent the au tomated system from being activated involuntarily The customer shall not under any circumstances attempt to repair or tune the automation and must call a qualified techni cian only Connect the automation...

Page 4: ...losing swap the wires from 14 and 15 terminals Close the gate and re lock the motor 04 When the gate arrives at the closed position press the SW1 PROGRAM button located on the control board for 2 se conds until the CODE LED see connection diagram page stays illuminated immediately press the transmitter button you want to be the total opening key NOTE When the transmitter button is pressed the CODE...

Page 5: ...ds before start opening com mences DIP 6 ON Enables more force torque during the opening operation The motor force will be double and sensitivity less during opening of that set by TR11 and during closing will be as per the setting of TR11 NOTE USED ONLY FOR OVERHEAD GARAGE DOORS APPLI CATION DIP 6 OFF Enables anti crushing function during opening and closing has the same obstacole sensitive funct...

Page 6: ...cept wire safety edges USE DIP 10 to set function ON BOARD MAGNETIC LIMIT SWITCH FUNCTION the control unit is equipped with a CN2 connector to accommodate a ma gnetic limit switch module directly welded on control panel on demand and just for Z01 model BATTERY EMERGENCY FUNCTION BLACK START The control board is equipped to operate in emergency with a single 12v battery and with a battery rechargin...

Page 7: ...PG7 ZCOMV2 CONTROL PANEL COMANDO 24V CONNECTIONS ...

Page 8: ... CLOSURE for other configuration see the DIP SWICH paragraph OFF DIP 2 ON OFF DIP 3 ON GATE PAUSE BEFORE CLOSING 60 SECOND OFF GATE PAUSE BEFORE CLOSING 15 SECOND DIP 4 ON SOFT STOP ENABLED OFF SOFT STOP DISABLED DIP 5 ON BLINK 2 SECONDOS BEFORE OPENING ENABLED OFF BLINK 2 SECONDOS BEFORE OPENING DISABLED DIP 6 ON ANTI CRUSHING FUNCTION DIFFERENT SENSIVITY WHILE OPENING AND CLOSING GARAGE DOORS OF...

Page 9: ...PG9 ZCOMV2 CONTROL PANEL COMANDO 24V FOTO FOTO 180 PHOTOCELLS CONNECTIONS ...

Page 10: ...PG10 ZCOMV24 CONTROL PANEL COMANDO 24V FOTO IN FOTO BATTERY ...

Page 11: ...EN CLOSE POSITION CONNECTION NOTE ON BOARD MAGNETIC LIMIT SWITCH FUNCTION the control unit is equipped with a CN2 connector to accommodate a magnetic limit switch module directly welded on control panel on demand and just for Z01 model will be also provided two magnetic stoppers for end limit switch positions ...

Page 12: ...d posi tion Lock motor again and turn off power supply for 5 seconds Reconnect it and send start si gnal using transmitter Gate opened but didn t close again Check if there is any obstacle in front of the photocells Check if any of the control devices key selector push button video intercom etc of the gate are jammed and sending permanent signal to control unit Consult a qualified ZERO tech nician ...

Page 13: ...ere is some security system malfunction photocells safety edges etc 1 Close with a link wire all safety systems on the control board check manual of the control board in question If the automated system starts working normally check for the problematic device 2 Remove one link wire at a time until you find the malfunction device 3 Replace it for a functional device and check if the motor works cor...

Page 14: ...CE Directive and that all the rules and or technical specifications shown below have been applied EN 60335 1 EN 60204 1 EN 55014 EN 6100 3 2 EN 6100 3 3 EN 6100 4 2 EN 6100 4 4 ENV50140 EN50081 1 EN50082 1 ALTAVILLA VICENTINA VI Italia 01 07 2016 and he also declares that it is not allowed to commission the device until the machinery where it will be incorporated or who se it will become a compone...

Page 15: ...PG15 ZCOMV2 CONTROL PANEL COMANDO 24V ...

Page 16: ...PG16 ZCOMV24 CONTROL PANEL COMANDO 24V ZERO SRLS Via Olona 110 Gallarate VA ITALIA info miozero it www miozero it ...