5.2 - Servicing the Array
Remove modules by column to access a faulty module. See Chapter 6 for tool use instructions.
SVC-A: Start at the top of the column with the faulty module.
Work from the top down, removing one
module at a time.
SVC-B: Remove the top row Interlock(s).
Place the Zep Tool over the fastener
with the 3 aligned with the reference
mark on the Interlock.
Rotate the Zep Tool CCW to Position 1.
Repeat for the second fastener.
CAUTION: Turn to Position #1
exactly.
SVC-C: Remove Cam Feet.
Use Flat Tool to loosen Cam Foot 1/4
turn as shown.
Use Flat Tool to rotate Cam Foot as
shown and disengage from groove in
module.
Slide the Cam Foot out and away from
the Module and Spanner Bar.
x
1
2
1
2
3
4