ZoningBOX 6 / ZoningBOX 4
Technical Support:
28
Note
:
ZoningBOX does not support scene saving
.
ETS PARAMETERISATION
Figure 22.
Zoning - Scenes
After having enabled the Scenes function from the Configuration tab (see section
), the “
Scenes
” object will become available, together with the following
parameters:
Scene n
[
disabled
/enabled
]: enables
or disables scene “n” (up to six).
➢
Scene number
[
1
…64
]: value that will trigger the execution of the scene, if
received through the “
Scenes
” object.
➢
Group of Zones
[
1
/2
]: zone group (1 or 2, if two groups have been
parameterised; see section 2.2.1) the scene execution will apply to.
➢
Operating Mode
[
No Change
/ Heat / Cool / Fan / Dry
]:
HVAC mode to be
set on the execution of the scene.
➢
Fan Mode
[
No Change / Auto / Manual
]: HVAC mode to be set on the
execution of the scene. This parameter is only available if "Auto + Manual"
is selected as the fan mode in the
Fan
section (see 2.2.4).
The latter
(“Manual”) entails configuring an additional parameter: