TMD-Display One
Technical Support:
http://zennioenglish.zendesk.com
44
The value ranges depend on the above two parameters:
1 byte unsigned: 0 – 255.
1 byte signed: -128 – 127.
2 bytes unsigned: 0 – 65535.
2 bytes signed: -32768 – 32767.
Minimum Value
: sets which value from the available range will be the
minimum value permitted by the control.
Maximum Value
: sets which value from the available range will be the
maximum value permitted by the control.
Short Increment
: sets the increase or decrease to be applied to the current
value on every short press over the increase or decrease buttons,
respectively (i.e., the smaller the increment, the more presses will be
required).
Long Increment
: sets the increase or decrease to be applied to the current
value on every long press over the increase or decrease buttons, respectively
(i.e., the smaller the increment, the more presses will be required).
Link the control with a box in the display
: sets the area of the display
where to show the indicator of this control, i.e., the current numeric value.
See section 2.4 for details.
LED lighting
: analogous to the homonymous parameter for the previous
functions (see above). In this case, the only options are “Regular” and
“Dedicated Object”.