TMD-Display One
Technical Support:
http://zennioenglish.zendesk.com
41
Shutter
Figure 32
Pair Buttons – Shutter.
The move orders will be sent through “
[Btn] [X] Shutter - Move
”, while the stop orders
will be sent through “
[Btn] [X] Shutter Stop/Step
” (for Standard type) or “
[Btn] [X]
Shutter - Stop
” (for Hold & Release type).
The parameters for this function are:
Type
: sets the desired behaviour of the buttons, “Standard” or “Hold &
Release” (the differences between them have been explained in previous
pages).
Action
: assigns each of the two buttons the order to be sent:
“Left=Down; Right=Up”.
“Left=Up; Right=Down”.
Note
:
this parameter will remain hidden unless having selected “Every button
pair is configured separately” in
Action of the pair buttons
(see
section
2.3.1).
LED lighting
: analogous to the homonymous parameter for the previous
functions (see above). In this case, the only options are “Regular” and
“Dedicated Object”.