B&B TRENDS SL accepts no liability for any damage that may be caused to people, animals or objects owing to 

failure to observe this warning correctly.

INSTALATION (Fig. 3)

Install in accordance with applicable national safety standards. 
1 Place the unit on a hard, rigid, flat, stable, horizontal surface free from vibration.
2 Keep all flammable materials away from the product, such as furniture, clothing, paper, curtains, etc.
Keep them at least 50 cm away from the unit. It is recommended to keep the air inlet and air outlet of the unit free 

of objects: at least 1 meter from the air outlet and 50 cm from the air inlet behind the unit.
(3) Never place over the bathtub if the unit is located in the bathroom. Maintain at least a distance of more than 60 

cm to prevent splashing, as shown in the figure.

INSTRUCTIONS FOR USE

The safety instructions marked at the beginning of this manual must be followed at all times when using this 

product.
Follow the instructions below in order to switch on the appliance:
1. Remove the product from its original packaging taking special care not to damage any of its parts. Do not use 

excessive force to remove the product from the box.
2. Switch on the appliance by selecting from the three speed settings (C).
3. Adjust the temperature using the thermostat control (D). The unit will be turned off automatically once it has 

reached the selected temperature. lf the temperature of the room drops the product will turn back on, thus 

keeping the temperature selected by the thermostat.

Repair:
Only specialized personnel should perform repairs to this electrical appliance. Any incorrect  ly performed repair 

can lead to considerable hazards for the user. In the event of repair, please always contact our aftersales service. 

Failure to observe these instructions will lead to the total loss of the product warranty.

TROUBLESHOOTING

Possible operating anomalies.

INCIDENT

CAUSE

SOLUTION

The device does not work

Appliance not switched on.

Switch on the appliance using 

the speed button.

The unit is on but the selec-

ted temperature level in the 

thermostat is lower than the 

temperature of the room.

lncrease the temperature level 

ofthe thermostat (D)

lnformation requirements for electric local space heaters

ITEM

SYMBOL  

VALUE

UNIT

PARAMETER

UNIT

Heat output

Type of heat input, far electric storage local space heaters 

only

Nominal heat 

output

P nom

1,8-2,0

KW

Manual heat charge control, with integrated 

thermostat

No

Mínimum heat 

output (indica-

tive)

P min

0,9

KW

Manual heat charge control with room and/or 

outdoor temperature feedback

No

Maximum 

continuous heat 

output

P max,c

2,0

KW

Electronic heat charge control with room and/

or outdoor temperature feedback

No

Auxiliary electri-

city consump-

tion

Fan assisted heat output

No

At nominal heat 

output

el max

0,000

KW

Type of heat output/room temperature control 

(select one)

At mínimum 

heat output

el min

0,000

KW

Single stage heat output and no room tempe-

rature control

No

In standby mode el SB

0,000

KW

Two or more manual stages, no room tempera-

ture control

No

With mechanic thermostat room temperature 

control

Yes

With electronic room tempera  ture control

No

Electronic room temperature control plus day 

timer

No

Electronic room temperature control plus week 

timer

No

Other control options (multiple selections 

possible)

Room temperature control, with presence 

detection

No

Room temperature control, with open window 

detection

No

With distance control option

No

With adaptive start control

No

With working time limitation

No

With black bulb sensor

No

CONTACT INFORMATION

B&B TRENDS, S.L. - C. Cataluna, 24 

P.I. Ca N’Oller 08130

Santa Perpetua de Mogoda (Barcelona) - Espana 

C.I.F. B-86880473

Summary of Contents for ZFH1900

Page 1: ...paces or occasional use INSTRUC IUNI DE UTILIZARE Aeroterma Acest produs este potrivit doar pentru spa ii bine izolate sau pentru utilizare ocazional EN RO BENUTZERHANDBUCH Heizl fter Das Produkt ist...

Page 2: ...pod nadzorem lub wcze niej otrzyma y instrukcje dotycz ce korzystania z urz dzenia w spos b bezpieczny i rozumiej zwi zane z tym zagro enia Dzieci nie mog bawi si urz dzeniem Czyszczenie i konserwacja...

Page 3: ...t rych istnieje ryzyko rozprysk w z g ry takich jak azienka kuchnia itp Jednak zar wno instalacja elektryczna produktu jak i spos b jego wykorzystania musz by zgodne z obowi zuj cymi krajowymi normami...

Page 4: ...iem ciep a promieniowania Nie DANE KONTAKTOWE B B TRENDS S L C Cataluna 24 P I Ca N Oller 08130 Santa Perpetua de Mogoda Barcelona Espana C I F B 86880473 CZYSZCZENIE I KONSERWACJA PRODUKTU Od czy urz...

Page 5: ...This symbol means that the product should not be covered This appliance is intended for use at a maximum altitude of 2000m above sea level IMPORTANT WARNINGS This device is intended solely for domesti...

Page 6: ...ur aftersales service Failure to observe these instructions will lead to the total loss of the product warranty TROUBLESHOOTING Possible operating anomalies INCIDENT CAUSE SOLUTION The device does not...

Page 7: ...GEN ERF LLT UND SIE ZUFRIEDEN STELLT ACHTUNG BITTE LESEN SIE DIE GEBRAUCHSANWEISUNG VOR DER ANWENDUNG DES PRODUKTS AUFMERKSAM DURCH BEWAHREN SIE DIESE ZUR SP TEREN EINSICHTNAHME AN EINEM SICHEREN ORT...

Page 8: ...iert dass er in jedem Raum benutzt werden kann auch in solchen in denen die Gefahr von Spritzern von oben besteht wie z B im Badezimmer in der K che usw Sowohl die elektrische Installation des Produkt...

Page 9: ...kontrolle mit Pr senzerken nung Nein Raumtemperaturkontrolle mit Erkennung offener Fenster Nein mit Fernbedienungsoption Nein mit adaptiver Regelung des Heizbeginns Nein mit Betriebszeitbegrenzung Nei...

Page 10: ...h specifickou p i Za zen ozna eno t mto piktogramem nesm b t p ikr v no Spot ebi je ur en k pou it v maxim ln nadmo sk v ce 2000 m n m D LE IT UPOZORN N Za zen je ur eno pouze k pou it v dom cnostech...

Page 11: ...zen je zapnut ale teplota zadan na termostatu je ni ne teplota v m stnosti Zvy te teplotu regul torem termostatu D Po adavky ohledn poskytnut informac tykaj c ch se lok ln ch elektrick ch oh va ur en...

Page 12: ...VYBRALI ZELMER VER ME V M N V ROBOK PRINESIE VE A RADOSTI A BUDETE S N M SPOKOJN UPOZORNENIE PRED POU IT M V ROBKU SI POZORNE PRE TAJTE TIETO POKYNY N VOD NA POU ITIE SI USCHOVAJTE NA BEZPE NOM MIESTE...

Page 13: ...va vo v etk ch priestoroch vr tane tak ch v ktor ch existuje riziko postriekania zhora ako s k pe a kuchy a at Av ak z rove elektrick in tal cia ako aj sp sob jeho pou vania musia sp a platn n rodn b...

Page 14: ...os vo by nie ko k ch nastavenie teploty v interi ri s detekciou pr tomnosti automatick m vypnut m Nie nastavenie teploty v interi ri s detekciou otvoren ho okna Nie s mo nos ou regul cie na dia ku Nie...

Page 15: ...k sz l ket bedugni szab lyozni tiszt tani nem szabad illetve nem szabad karbantart si munk latokat v gezni k FIGYELEM A term k egyes r szei t lhev lhetnek s g si s r l seket okozhatnak K l n s figyele...

Page 16: ...helytelen l v gzett jav t s jelent s kock zatot hordoz a haszn l sz m ra Jav t s eset n vegye fel a kapcsolatot a forgalmaz szerv z nkkel Amennyiben nem tartja be ezeket az utas t sokat teljesen elves...

Page 17: ...S FUNC IONEZE NTR UN MOD SATISF C TOR I MUL UMITOR PENTRU DUMNEAVOASTR AVERTISMENT V RUG M S CITI I CU ATEN IE ACEST MANUAL NAINTE DE A UTILIZA PRODUSUL I S L P STRA I NTR UN LOC SIGUR PENTRU CONSULT...

Page 18: ...de sus de exemplu n baie buc t rie etc Cu toate acestea at t instala ia electric a produsului c t i modul n care este utilizat trebuie s fie compatibile cu standardele na ionale de siguran aplicabile...

Page 19: ...Nu Alte op iuni de control se pot selecta mai multe variante controlul temperaturii camerei cu detectarea prezen ei Nu controlul temperaturii camerei cu detectarea unei ferestre deschise Nu cu op iun...

Page 20: ...39 38 PL PL RU RU ZELMER A B C D 8 3 3 8 3 8 2000 4 2...

Page 21: ...3 60 1 2 C 3 D D P nom 1 8 2 0 P min 0 9 P max c 2 0 KW Electronic heat charge control with room and or outdoor temperature feedback No el max 0 el min 0 el SB 0 B B TRENDS S L C Cataluna 24 P I Ca N...

Page 22: ...43 42 PL BG PL RU 2012 19 UE WEEE ZELMER A 8 3 3 8...

Page 23: ...45 44 PL PL BG BG 3 8 2000 4 2 IPX1 B B TRENDS SL Fig 3 1 2 50 1 50 3 60 1 2 3...

Page 24: ...47 46 PL PL BG BG P nom 1 8 2 0 P min 0 9 P max c 2 0 el max 0 el min 0 el SB 0 B B TRENDS SL C Cataluna 24 PI Ca N Oller 08130 Santa Perpetua de Mogoda Barcelona Espana CIF B 86880473 2012 19 WEEE...

Page 25: ...49 48 PL PL UA UA ZELMER A B C D E 8 3 3 8 3 8 2000 4 2...

Page 26: ...A UA IPX1 B B TRENDS S L Fig 3 1 2 50 1 50 3 60 1 2 C 3 D D P nom 1 8 2 0 P min 0 9 P max c 2 0 el max 0 el min 0 el SB 0 B B TRENDS S L C Cataluna 24 P I Ca N Oller 08130 Santa Perpetua de Mogoda C I...

Page 27: ...rz dzenia wynikaj ce z niew a ciwego wykonania Urz dzenia b d jego cz ci kt re czyni je nieprzydatnym do u ytkowania zgodnie z przeznaczeniem 3 Odpowiedzialno z tytu u gwarancji obejmuje tylko wady po...

Page 28: ...uprawnionego oraz telefon kontaktowy 13 Urz dzenie powinno zosta przygotowane do transportu zgodnie z wymogami okre lonymi przez wskazany przez Gwaranta podmiot wiadcz cy us ugi kurierskie W przypadku...

Page 29: ...57 56...

Page 30: ...59 58...

Page 31: ...60...

Page 32: ......

Page 33: ...09 2022 WWW ZELMER COM SERIES ZFH MOD ZFH1900 ZFH1900P 220 240V 50 60Hz 1800 2000W TYPE FH205 S Made in China B B TRENDS S L C Catalu a 24 P I Ca N Oller 08130 Santa Perp tua de Mogoda Barcelona Spain...

Reviews: