![Zelmer Aquawelt Plus ZVC762 User Manual Download Page 42](http://html1.mh-extra.com/html/zelmer/aquawelt-plus-zvc762/aquawelt-plus-zvc762_user-manual_3372047042.webp)
46
VC7920-003_v01
cleaners type VC7920.0. To set demanded
brightness of LEDs you should simultaneously
press the power adjustment buttons + and –
(9), and then holding them down you should
turn on the vacuum cleaner by pressing the
“ON / OFF” button (8). The LED for power
levels MIN, 2, and MAX turn on, and the motor
stays turned off. Next by pressing the power
adjustment b/– (9) you can respectively
increase or decrease the brightness of power
level indicator (10), and the clogged air inlet
indicator (12). It is not possible to change LED
brightness for the pump operation indicator
(6). After setting a desired LED brightness, it is
necessary to turn off the vacuum cleaner using
the ON/OFF button (8). In this way you leave
the LED brightness adjustment function mode,
and the set LED brightness level is stored.
The vacuum cleaner is equipped with a power
limiting function should the inlet opening be
clogged or the SAFBAG dust bag full. It is
manifested by a pulsing limitation of the motor
power and the lighting up of the clogged air
inlet indicator (12) while the vacuum cleaner
is operating at full power (type VC7920.0). In
such a case switch off the vacuum cleaner
by pressing the on/off button (8), unplug the
appliance and clear the tubes or replace the
SAFBAG dust bag.
SAFBAG dust bag disassembly/assembly
●
Remove the dry filtration module with the SAFBAG
(21)
dust bag from the container.
1
Pull the SAFBAG dust bag interlock fastening and pull
the interlock aside.
2
Pull the fastening which attaches the SAFBAG dust bag
to the basket to release the dust bag plate.
3
Remove the dust bag.
4
Insert the SAFBAG dust bag according to the arrow
printed on the bag so that the lower part of the bag plate is in
the slot of the housing. Press the upper part of the bag plate
to the fastening until you hear a characteristic click and close
the SAFBAG dust bag interlock.
●
Insert the dry filtration module with the SAFBAG
(21)
dust bag to the container.
VACUUM CLEANING WITH THE USE OF THE
WATER FILTER MODULE
1
Press and hold the container lid opening button
(2)
and
lift the container lid.
2
Insert the partition to the grooves in the container so that
the shutters are directed downwards. Make sure the partition
is correctly mounted in the container i.e. the partition fins
should cover the protrusion in the container.
3
Fill the container with 1,3–1,5 liter of water. The water level
should be in the range marked on the wall of the container.
D
E
Do not operate the appliance with an empty
container while vacuum cleaning with the use
of the water filter module.
4
Cover the container with the filter unit.
●
Prepare the vacuum cleaner for operation according
to section B.
●
The vacuum cleaner starts at the same power level
it had been working before it was turned off. Set the
desired power value (this function is only available in
vacuum cleaners type VC7920.0) by pressing the power
adjustment b/-
(9)
.
Do not operate the appliance for too long
without replacing the water in the container.
WET VACUUMING AND WET CLEANING
Before using the wet cleaning function thoroughly vacuum
the surface to be cleaned.
Before operating the vacuum cleaner make sure the
container is empty and the water filter module and the filters
are clean.
1
Press and hold the container lid opening button
(2)
and
lift the container lid.
2
Remove the container together with the water filter
module (filter unit and partition) from the vacuum cleaner.
3
Remove the cleaning liquid container
(23)
by pulling it by
the handle and lifting it upwards.
4
Open the filler cap and fill the cleaning fluid reservoir
(23)
with cleaning agent (a mixture of cleaning fluid G 500 O-Tens
Tensidfreier Reiniger
(29)
and cold water). Use the amounts
stated on the fluid bottle label:
–
“G 500 O-Tens Tensidfreier Reiniger” manufactured by
BUZIL, Germany.
●
Close the filler hole of cleaning fluid reservoir with the cap.
Before wet cleaning the carpet, check the
colour fasteness of cleaned carpet . Put a small
amount of prepared solution on white cloth and
clean manually the carpet at least visible place.
If the cloth is dyed, it means that the carpet
colours are not permanent and the carpet
cannot be cleaned using cleaning fluid G 500
O-Tens Tensidfreier Reiniger.
5
Insert the cleaning liquid container
(23)
back to the
previous position and press the container to fix it correctly
(proceed in the reverse order as in case of removing the
container).
6
Insert the container together with the water filter module
(filter unit and partition) to the vacuum cleaner.
For protection against the formation of foam or at its
formation, when cleaning fill the rear tank with an anti-
foaming agent (29) recommended by the company
ZELMER, in the amounts specified on the label:
–
“G 478 Entschäumer D” manufactured by company
BUZIL, Germany.
F