  Functional description / use

  Functional description / use

Brief description of the camera system

The AxioCam ERc 5s CMOS camera is intended as a camera for connection to 
microscopes and produces photos with a size of up to 5 megapixels. The image data 
can be 

• 

saved to a memory card (stand-alone operation), 

• 

immediately viewed on a connected monitor, or 

• 

 immediately displayed via the configuration program and processed further on 

a PC using the AxioVision programs (LE or full version).

Various standard analog and digital data interfaces make it possible to connect the 
camera to different output devices for co-observation or recording.

The camera quality is configured and optimized by means of settings in the 
configuration program supplied. This ensures that the settings are applied during 

stand-alone operation – without connection to a PC.

Purpose

The AxioCam ERc 5s is a microscope camera that is suitable for use as an accessory 
for educational and routine microscopy in laboratory environments and for use by 
trained laboratory personnel. 

• 

 The camera must be permanently connected to Carl Zeiss light microscopes 
or suitable light microscopes of other manufacturers by means of suitable 
adapters. 

• 

 The camera must be connected to microscope ports intended for this purpose; it 
must not be connected to the eyepiece. 

• 

 The camera is not suitable for fluorescence microscopy.

• 

 The camera is configured and controlled by means of the PC software supplied, 

which also allows the photos to be further processed and saved. 

• 

 The camera can be connected to co-observation and recording devices by 
means of various standardized data interfaces. Only pre-fabricated, standard 
connection cables may be used.

Obligations, assurances and exclusions

The envisaged uses of the camera system are general tasks and applications in the fields of 

microscopy and image analysis.  

This Infoflip and other information on the camera system provide only a general description of 

technical procedures and instructions. It may not be appropriate to follow the instructions in 
each individual case. Please contact the Carl Zeiss support team if in doubt!

All user information on the camera system and this Infoflip are protected by copyright. Carl 

Zeiss has reserved all rights to this information. The production of copies or partial copies 

and translation into other languages are also not permitted without specific written consent. 

Copies intended for personal use are excluded from this.

Carl Zeiss would like to point out that the details contained in all the user information relating 
to the camera system are updated on an ongoing basis in line with any technical changes that 

may be necessary. This Infoflip therefore only reflects the technical status of the camera system 
at the time of going to print. You will find up-to-date information relating to the instructions 

and the camera system on our website!

Before installing and operating the camera system, make sure you have read and understood 

all the information in this Infoflip and in the other accompanying documents! Carl Zeiss does 

not assume any liability or give a warranty for applications other than those described here. 

The same applies to procedures that are not described in this Infoflip and do not produce the 

desired result, or even result in damage.

Summary of Contents for AxioCam ERc 5s

Page 1: ...The purpose of the white balance is to calibrate the camera to the color temperature of the incident light and thereby prevent color cast However the automatic white balance that is normally used doe...

Page 2: ...ith the manufacturer concerned Always follow the instructions for the microscopes when it comes to connecting and operating external cameras Damage due to short circuit If the cable of the mains power...

Page 3: ...observation and recording devices by means of various standardized data interfaces Only pre fabricated standard connection cables may be used Obligations assurances and exclusions The envisaged uses o...

Page 4: ...Included with product Included with product Included in standard package AxioCam ERc5s camera with dust cap A to Mini B type USB cable 1 Camera 2 USB cable In addition DVD containing the configuration...

Page 5: ...hat may be present from the microscope s phototube 2 Place the unit comprising the camera and C mount adapter onto the microscope s phototube 3 Align the camera by rotating it so that the front of the...

Page 6: ...ve problems with the AWB please use a conversion filter to adjust the color temperature of the illumination to the camera limit Operation without PC connection Operation without PC connection Operatin...

Page 7: ...setup gives you the option of installing the configuration program for the camera the free imaging software AxioVision LE or both together To do so follow the instructions in the dialog boxes on the s...

Page 8: ...n the case of darkfield images 3 Saving and closing This button gives you the option of transferring the settings currently specified on the property pages to the camera s internal memory and then clo...

Page 9: ...opening so that it is impermeable to light Saving property page Naming Enter a prefix into the text field that will appear in front of the image number in the file name on the memory card Resolution...

Page 10: ...interface in US television format General Settings property page Reload Factory Defaults Resets camera to a defined status Note Your individual settings will be lost during this process Time And Date...

Page 11: ...e image subsequently click on the Properties button and then on the Display property page Adjust the image individually Brightness and Contrast sliders Set brightness and contrast automatically Min Ma...

Page 12: ...are update does not work An SD card must be inserted for an update to take place Insert a formatted unprotected SD card with at least 10 MB of free memory space No live image of the camera is visible...

Page 13: ...ol or maintenance elements on the camera housing or inside the camera that the user would be able to repair him herself If you are unable to resolve a problem using the troubleshooting table on the ba...

Page 14: ...For your notes For your notes For your notes...

Page 15: ...routine microscopy and image analysis The camera should only be installed and operated by trained individuals who have been informed about the possible risks associated with microscopy and the area o...

Reviews: