15. 

TPS 

 

 

Enter 

Set Ign.

 

menu and move to 

TPS

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to 

confirm. 

 

Enable/disable 

TPS

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 

 

16. 

Set TPS close [0%] 

(if TPS enabled)

 

 

TPS close position must be calibrated to ensure correct TPS operation!  
 

 

Enter 

Set Ign. 

menu and move to 

TPS close [0%] 

with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 

Leave throttle at close position and confirm calibrating with pressing 

'

ENTER

'

 , or exit 

calibration with pressing 

'

-

'

. Displayed number should be between 0 and 500. 

 

 

17. 

Set TPS open [100%] 

(if TPS enabled)

 

 

TPS open position must be calibrated to ensure correct TPS operation!  
 

 

Enter 

Set Ign. 

menu and move to 

TPS open [100%] 

with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 

Move throttle to maximum open position and confirm calibrating with pressing 

'

ENTER

'

 , 

or exit calibration with pressing 

'

-

'

. Displayed number should be between 500 and 1010. 

 
 

18. 

TCT mode 

 

Throttle Close spark Termination mode, reduces number of sparks (spark is active 
every third revolution) above 8000rpm, when throttle is closed. TCT mode ensure better 
engine cooling. 

 

 

Enter 

Set Ign. 

menu and move to 

TCT mode 

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 

to confirm. 

 

Enable, or disable 

TCT mode

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 
This setting is primarily for race use, for normal road use the recommended setting is 
'DISABLED'. 
If you getting errors on the rev counter then 'DISABLE' this setting. 

 
  

19. 

IGN. MAP SW 

 

Enabling, or disabling ignition map switch, for changing ignition maps while riding. 
 

 

Enter 

Set Ign. 

menu and move to 

Ign. Map SW 

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 

Enable or disable external switch with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm.

 

 

Summary of Contents for PDCI-NS1V

Page 1: ...t light and power jet output 5 Amp constant spark energy from idle to 13000 RPM 50mJ Important Circuit is fully protected against reverse polarity from firmware 31 170203 Features fast power up also s...

Page 2: ...es Danger of electric shock Avoid connecting PDCI to 12V power supply before connecting to ignition coil High voltage is generated and touching free wires can cause electric shock or damage the unit 1...

Page 3: ...V PARAMETERS SUBMENU Load PV Curve load select PV curve Save PV Curve save new PV curve Set PV Curve PV curve parameters submenu Deviation deviation of PV position Close Position max close PV position...

Page 4: ...g processing don t make unreasonable curve course Every time you make any changes to ignition curve it is automatically saved to position 0 Later you can save it to any other position 1 or 2 Curve Exa...

Page 5: ...can save it to any other number 1 or 2 Ignition Map Example 5 2 Change NUMBER OF IGNITION CURVE POINTS Move to Nr of Points with pressing or and press ENTER to confirm Select number of ignition point...

Page 6: ...ded With Advance 1 0 0deg ignition map is unchanged Enter Set Ign menu and move to Advance 1 with pressing or and press ENTER to confirm Set advance with pressing or in 0 1deg steps and press ENTER to...

Page 7: ...ENTER to confirm Enable or disable Smart Shift function with pressing or and press ENTER to confirm 11 REV LIMIT Enter Set Ign menu and move to Rev Limit with pressing or and press ENTER to confirm S...

Page 8: ...atic angle just to have starting point look at drawing below Anticlockwise rotation TRIGGER POINT TDC static angle Clockwise rotation TDC TRIGGER POINT static angle program CDI with measured approxima...

Page 9: ...n the rotor and stator Result of above procedure is very accurate static angle 13 COMPENSATION It is compensation of signal delay from pickup to spark plugs You can check this delay with stroboscope l...

Page 10: ...if TPS enabled Three duty cycle curves for different throttle positions can be programmed Each curve can be programmed in 8 rev points Enter Power Jets menu and move to set Power Jet 1 with pressing o...

Page 11: ...imum open position and confirm calibrating with pressing ENTER or exit calibration with pressing Displayed number should be between 500 and 1010 18 TCT mode Throttle Close spark Termination mode reduc...

Page 12: ...to confirm Change Stop SW Mode with pressing or and press ENTER to confirm 22 Tach Ratio Tachometer output pulse ratio can be set to 1 or 2 pulses per revolution Enter Set Ign menu and move to Tach Ra...

Page 13: ...oint Exit exit submenu Important To avoid wrong processing don t make unreasonable curve course Every time you make any changes to PV curve it is automatically saved to number 0 Later you can save it...

Page 14: ...sition with pressing or and press ENTER to confirm 27 Open Position Max open position must be calibrated Max open position is when curve is set to 100 Open position can be moved to any desired positio...

Page 15: ...mation displayed on the programmer is software version With programmer you can watch revs calculated advance ignition angle TPS position depends on setting in the menu Information You can connect or d...